EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - EMERGENCY AREA LIGHT IN DOOR 3 CROSSOVER CEILING INOP RELAMPED PER AMM 33-51-03-960-801 CK OK.
EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - EMERGENCY AREA LIGHT AT DOOR 2 GALLEY, LEFT, INOP LOCATOR PHOTO RELAMPED PER AMM 33-51-03-960-801 CK OK.
EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - EMERGENCY AREA LIGHT ABOVE ROW 1AB INOP RELAMPED PER AMM 33-51-03-960-801 CK OK.
POWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - AFTER C/W BATTERY PACK DEEP-CYCLE PROCEDURE, FOUND BATTERY M33094 WILL NOT HOLD A CHARGE FOR THE FULL 15 MINUTES. REPLACED BATTERY PACK PER AMM 33-51-06-960-802 TEST OK.
DR 4R M33408 EMER LT BATTERY DEEP CYCLE PROCEDURE FAILED. EMER LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.
DR 2R M33097 EMER LT BATTERY DEEP CYCLE PROCEDURE FAILED. EMER LT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.
SUPPORT TASK - DR 1L M33424 EMER LT BATTERY DEEP CYCLE PROCEDURE FAILED. DR 1L M33424 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.
SUPPORT TASK - DR L1 M33424 EMER LT BATTERY CHARGER DEEP CYCLE PROCEDURE FAIL DR L1 M33424 EMER LT BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM33-51-06.
DR 4 M33408 EMER LT BATTERY CHARGER DEEP CYCLE PROCEDURE FAIL DR 4R M33408 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM33-51-06 ATTACH FORM 44.0008 ITEM 1 TO 2 ACCOMPLISHED.
DR L2 M33099 EMER LT BATTERY DEEP CYCLE TEST FAILED. DR L2 M33099 EMER LT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.
DOOR 4R EMER LIGHT BATTERY M33409 DEEP CYCLE TEST FAILED. DOOR 4R EMER LIGHT BATTERY PACK M33409 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
LH ELEVATOR I/B ACTUATOR FITTING 1EA CRACK WAS FOUND APPROX 3/8" LENGTH TRANSFER REF. NON-ROUTINE HX NRC WO.4880852 AND ORIGINATE BY EMP NO. V925919 ACCOMPLISHED ESFR ENTRY LH ELEVATOR I/B ACTUATOR FITTING REPLACED AS PER EA5510-01896 REV C OP 018 , SFR 958 RAISED WORK ACCOMPLISHED BY MECHANIC V893003 INSPECTED BY V912779 ADD EMP:V912779 RII INSPECTED BY HX170267 ADD EMP:V896876 LH ELEVATOR I/B ACTUATOR FITTING REPLACED AS PER EA5510-01896 REV C OP 018 WORK ACCOMPLISHED BY MECHANIC V893003 INSPECTED BY V912779 RII INSPECTED BY HX170267 ADD EMP:V896876
PDA 2 RAMP REPORTED GND POWER ASSIST HOOK AND STRAP MISSING SUSPECT OLD WORN STRAP AND HOOK ARE STIIL ON PUSH TRACTOR IN OGG. REPLACED FWD GND PWR CORD ASSIST STEAP AND HOOK. ADD EMP:006156 HOOK, EXT. GND POWER CABLE. M&E 25-2441-3-0004.
BLEED LOSS BODY EICAS ADVISORY BLEED AIR SUPPLY VALVES ARE LATCHED CLOSED OR THE RESPECTIVE SWI TCHES ARE OFF, SO THAT BLEED AIR IS NOT SUPPLIED TO HYDRAULIC DE MAND PUMPS C1, AND C2, C HYDRAULIC RESERVOIR PRESSURIZATION, AFT CARGO HEAT AND POTABLE WATER TANK PRESSURIZATION. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2632062. FOUND APU AIR DUCT BROKEN IN L/H MLG WHEEL WELL. FLANGE SEPARATED FROM DUCT. REF 777 FIM TASK 26-18 TASK 804 PERFORMED MAINTENANCE MESSAGE CHECK NO CURRENT FAULTS ACTIVE LEAK INDICATION CAUSED BY BROKEN DUCT IN PREVIOUS UPDATE. INSPECTED LEFT MAIN GEAR WHEEL WELL. NO FURTHER DAMAGE NOTED. REMOVED AND REPLACED AIR DRIVEN PUMP AIR SUPPLY DUCT PER IPC 29-11-16-01 LEAK CHECK OK.
BE BUSINESS CLASS SEATS - INSPECTION (EC2525-02058) BE BUSINESS CLASS SEATS - INSPECTION - EMERGENCY PATH LIGHT BROKEN AT SEAT 3D AFT OF SEAT. SEE PHOTO REPLACED LENS REF IFM CMM 25-25-72 PARTS USED: 99-3350-3-0008,QTY :1
B777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY CHARGER TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960129 AND ORIGINATED . DR R3 M33401 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
B777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960138 AND ORIGINATED BY . DR R3 M33401 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 AND ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED.
B777-33-3-7019, DR L1 M33424 EMER LIGHT BATTERY CAPACITY CHECK FAIL. DR L1 M33424 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.
MAIN GEAR STEERING EICAS INTERMITTANT GROUND RETURN, PILOTS REPORT NO HIGH ENERGY STOP. LOCKED OUT MLG APPLYING MEL 3253A. STEERING AND COMPLIED WITH MEL. REQUESTING 3253A. TOMC APPROVES THE USE OF MEL 3253A FOR MAIN GEAR STEERING SYSTEM INOP. PER FIM 32-53 TASK 801, TROUBLE SHOT TO A FAULTY MGSCU. REMOVED AND REPLACED MGSCU REF AMM 32-53-02. OPS CHECK GOOD PARTS USED: 27-3250-9-0001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1617185 SN OFF 0351 UNIT, CONTROL, OFF 27-3250-9-0001 0351 ON 27-3250-9-0001 0164.CREW REPORTS NO HIGH STOP. BREAKS NOT HOT. OKAY TO CONTINUE
MAIN GEAR STEERING ECAM ON TO ROLL COMPLIED WITH MEL 3253A. LOCKED MAIN STEERING AND PULLED COMPLIED WITH MEL 3253A. LOCKED MAIN STEERING AND PULLED BREAKER BREAKER. OK TO DEFER MLG STEERING PER CREW TAKE OFF ROLL ABORTED 20 KTS NO BRAKE TEMP ISSUES
FUS UPPER SURFACE STA2108-STA2150 STR 1R-STR 3R FND PANEL TOUCH TO SKIN AREA CHAFING REF HAECO NON-ROUTINE NO.:9487764,ORIGINATE D BY EMP V916770,SPEC NO.B777-06-3-7175. TABLE 202/REPAIR 2 FIG 203. PERFORM EXTERNAL LFEC INSPECTION OF 30000 CYCLES WHICH EVER COMES LATER REF NDT PART 6, 53-00-06. CRITICAL ROW OF FASTENERS AT A INTERVAL OF 8000 FLIGHT CYCLES OR AIRCRAFT CURRENT HAS 17788 TC AND 96993:18 HAECO XMN REPAIRED AS PER SRM53-70-01 REPAIR 2 FIG 202 DETAIL A AND REPAIR B REV 88. THIS IS A REPAIR INSPECTION REQUIREMENT REF RII BY TA511. PER SRM 53-70-01 RPR2 TABLE 2 ACP EXTERNAL LFEC INSPECTION TOMC-APPROVAL FROM SC1ELBYC COMMENT OF THE CRITICAL ROW OF FASTENERS INSPECTION THRESHOLD OF 30,000 CYC (IS MEASURED FROM THE TIME THE AIRPLANE WAS DELIVERED) THEN AN INTERVAL OF 8000 CONCECUTIVE CYCLES THEREAFTER. ACP INTERNAL HFEC AND EXTERNAL LFEC INSPECTION OF THE CRITICAL ROW OF FASTENERS INTVL 8000C. DVI INTERVAL 16000 CYCLES PER TBL 202 INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. TOMC APPROVE : QC REVIEWED. TOMC APPROVE : QC REVIEWED.
FUS UPPER SURFACE STA2108-STA2150 STR 1R-STR 3R FND PANEL TOUCH TO SKIN AREA CHAFING. PERFORM EXTERNAL LFEC INSPECTION OF 30000 CYCLES WHICH EVER COMES LATER REF NDT PART 6, 53-00-06. CRITICAL ROW OF FASTENERS AT A INTERVAL OF 8000 FLIGHT CYCLES OR AIRCRAFT CURRENT HAS 17788 TC AND 96993:18 HAECO XMN REPAIRED AS PER SRM53-70-01 REPAIR 2 FIG 202 DETAIL A AND REPAIR B REV 88. THIS IS A REPAIR INSPECTION REQUIREMENT REF RII BY TA511.
CAB SEAT 16DG-28DG SEAT EMERGENCY LIGHT FOUND CAN NOT STAY ON FO R 15 MINUTES REF HAECO NON-ROUTINE NO.9487749,ORIGINATED BY EMP V903194,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V903194,REPLACED THE RELATED BATT AND CONDITION AL CHK "NORMAL" AND FUNCTIONAL TEST "NORMAL" REF AMM 33-51-06-96 0-802 REV95,IDT BY TA 407. THIS SHOULD BE SDR ITEM.
RH DOOR 4 MAIN AISLE EMERGENCY LIGHT CAN NOT STAY ON 15 MINUTES REF HAECO NON-ROUTINE NO.9490060,ORIGINATED BY EMP V903194,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905356,REPLACED THE M33409 BATTERY AND INSTALL ATION TEST FOUND RESULT "NORMAL" REF AMM 33-51-06-960-803 REV95, IDT BY TA407.
AFT ZONE SEAT EMERGENCY LIGHTS INOPERATION REF HAECO NON-ROUTINE NO.9491473,ORIGINATED BY EMP V905356,SPEC NO.B777-25-3-7250. PERFORMED BY EMP V905356,REPLACED THE M33401 BATTERY AND INSTALL ATION TEST FOUND RESULT "NORMAL" REF AMM 33-51-06-960-803 REV95, IDT BY TA407.
CABIN INSPECT FOUND THE L/H 4 DOOR EMERGENCY LT INOPERATION REF HAECO NON-ROUTINE NO.9491606,ORIGINATED BY EMP V905356,SPEC NO.B 777-25-3-7250. PERFORMED BY EMP V905356,REPLACED THE L/H 4 DOOR M33407 CHARGER ASSY AND OPERATION CHECK FOUND THE RESULT "NORMAL" REF AMM 33-51 -06-960-803 REV95,IDT BY TA625.
LH DOOR 4 MAIN AISLE EMERGENCY LIGHT CAN NOT STAY ON 15 MINUTES REF HAECO NON-ROUTINE NO.9490059,ORIGINATED BY EMP V903194,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905356,REPLACED THE M33407 BATTERY AND INSTALL ATION TEST FOUND RESULT "NORMAL" REF AMM 33-51-06-960-803 REV95. IDT BY TA407.
CABIN INSPECT FOUND THE R/H 2 DOOR EMERGENCY LT INOPERATION REF HAECO NON-ROUTINE NO.9491609,ORIGINATED BY EMP V905356,SPEC NO.B 777-25-3-7250. PERFORMED BY EMP V905356,REPLACED THE R/H 2 DOOR M33097 CHARGER ASSY AND OPERATION TEST FOUND RESULT "NORMAL" REF AMM 33-51-06-9 60-803 REV95,IDT BY TA625.
FUS. LOWER SURFACE AFT VACUUM BLOWER EXHUST VENT PORT SURROUND FOUND CORROSION. WERE ZERO TIMED WHICH SETS THE INITIAL INSPECTION AT 30,000 INSPECTIONS AT 4,000 FLIGHT CYCLES THEREAFTER. FLIGHT CYCLES SINCE THE REPAIR WAS INSTALLED AND REPETITIVE THE SKIN WAS REPAIRED PER SRM 53-70-01-2R-1 REPAIR 1. THIS IS A CATEGORY B REPAIR REQUIRING REPEAT INSPECTIONS. FASTENER HOLES RII BY TA594.
FUS. LOWER SURFACE AFT VACUUM BLOWER EXHUST VENT PORT SURROUND F ND CORROSION. WERE ZERO TIMED WHICH SETS THE INITIAL INSPECTION AT 30,000 INSPECTIONS AT 4,000 FLIGHT CYCLES THEREAFTER. FLIGHT CYCLES SINCE THE REPAIR WAS INSTALLED AND REPETITIVE THE SKIN WAS REPAIRED PER SRM 53-70-01-2R-1 REPAIR 1. THIS IS A CATEGORY B REPAIR REQUIRING REPEAT INSPECTIONS. FASTENER HOLES
EGT INDICATION (ENGINE) RED FIM TASK REF: PW 71-05 TASK 833 .DUE TO NR 2 ENGINE IFSD/UNCONTAINED ENGINE FAILURE, THIS EVENT IS CURRENTLY UNDER INVESTIGATION, AWAITING FINDINGS.
FUSELAGE SKIN AT BS 1850 - 1853, STRINGERS 41L - 42L WAS CORRODED. DISCOVERED DURING A C-3 CHECK. REPAIRED IAW EC/RA 5371-01009, PART 1A.
LEFT ELEVATOR, OTBD ACTUATOR FITTING, LOCATION E WAS FOUND CRACKED. APPROX 0.375 IN LENGTH. REPLACED THE LT ELEVATOR OTBD ACTUATOR FITTING IAW EA 5510-01896, REV C, OP 016.
AFT CARGO BAY BILGE STRINGER 49L.CLIP WAS FOUND CORRODED AT BS 1874. THE STRINGER CLIP WAS REPAIRED IAW EC/RA 5371-01011, REV.
BULK CARGO BAY BILGE AREA STA 1937 STR 43L FOUND CORROSION. THE STRINGER 43L WAS REPAIRED IAW EC/RA 5371-01008, REV.
OTBD SIDE OF THE RT BS 2370 PIVOT BULKHEAD FORWARD OUTER ANGLE WAS FOUND CRACKED. THE BULKHEAD ANGLE WAS REPAIRED IAW EA 5380-01113, OPS 012.
AFT CARGO BAY BILGE AREA BS 1874, STRINGERS 48L - 49L SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPAIRED IAW EC/RA 5371-01010, REV.
AFT CARGO BAY BILGE BS 1874, STRINGERS 44L-45L SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPAIRED IAW EC/RA 5371-01010, REV.
AFT CARGO BAY BILGE, BS 1874 STRINGERS 42L - 43L SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE REPAIRED IAW EC/RA 5371-01010, REV.
AFT CARGO BAY BILGE AREA BS 1874, STRINGERS 49L - 49R SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPAIRED IAW EC/RA 5371-01010, REV.
AFT CARGO BILGE STRINGER CHIP 43L WAS FOUND CORROED AT BS 1874. REPAIRED IAW EC/RA 5371-01011 REV.
OTBD OF THE BS 2370 PIVOT BULKHEAD, FORWARD OUTER ANGLE WAS FOUND CRACKED. THE BULKHEAD ANGLE WAS REPAIRED IAW EC/RA 5380-01113, OP 11.
AFT CARGO BAY BILGE AREA BS 1874, STRINGERS 46L - 47L, THE SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPAIRED IAW EC/RA 5371-01010, REV.
AFT CARGO BAY BILGE AREA, BS 1884 - 1890, STRINGER 45L UPPER & LWR AREA WAS FOUND CORRODED. THE STRINGER WAS REPAIRED IAW EC/RA 5371-01007, REV.
)BULK CARGO AFT OF BS 1958, STRINGER 42L WAS FOUND CORRODED. THE STRINGER WAS REPAIRED IAW EC/RA 5371-01005, REV.
AFT CARGO BAY BILGE, STRINGER 43L WAS CORRODED AT BS 1874. THE STRINGER WAS REPAIRED IAW EC/RA 5371-01008, REV.
AFT CARGO BAY BILGE, STRINGER 49L WAS FOUND CORRODED AT BS 1874. THE STRINGER WAS REPAIRED IAW EC/RA 5371-01006, REV.
BULK CARGO BAY BILGE, STRINGER 42L CORRODED AT BS 1937. THE STRINGER WAS REPAIRED IAW EC/RA 5371-01005, REV.
AFT CARGO BAY BILGE AREA, BS 1870 - 1874, STRINGER 48L WAS FOUND CORRODED. REPAIRED THE STRINGER IAW EC/RA 5371-01004, REV.
BULK CARGO FWD OF BS 1958, STRINGER 43L WAS FOUND CORRODED AND CRACKED. REPAIRED IAW EC/RA5371-01008, REV.
BULK CARGO, BS 1958, BETWEEN STRINGERS 42L AND 43L, THE SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.
AFT CARGO BAY BILGE AREA BS 1874 - 1885, STRINGER 44L WAS FOUND CORRODED. THE STRINGER WAS REPAIRED IAW ECRA 5371-01002, REV.
AFT CARGO BAY BILGE STRINGER 49R AT BS 1874 WAS FOUND CORRODED. THE STRINGER WAS REPAIRED AND REPLACED IAW ECRA 5371-01003, REV-.
AFT CARGO BAY BILGE AREA BS 1874, STRINGER 47L - 48L SHEAR TIE WAS FOUND CORRODED. THE SHEAR TIE WAS REPLACED IAW SRM 51-10-02, AND INSTALLED IAW SRM 51-40-02.
BS 2195.75 BETWEEN STRINGERS 6L AND 8L, THE SKIN HAD TWO FASTENER HOLES THAT WERE FOUND CRACKED. A REPAIR DOUBLER AND TRIPLER INSTALLED IAW EA 5300-01986, REV A, OP 007.
SKIN AT BS 2195.75, BETWEEN STRINGERS 6R AND 8R, TWO FASTENER HOLES FOUND CRACKED. A REPAIR DOUBLER AND TRIPLER WAS INSTALLED IAW EA 5300-01986, REV A, OP 010.
SKIN AT BS 2221.65, BETWEEN STRINGERS 9R AND 10R, WAS FOUND CRACKED. A REPAIR DOUBLER AND TRIPLER WAS INSTALLED IAW EA 5300-01986, REV A, OP 011.
L3 DOOR M33406 BATTERY PACK CAPACITY CHECK FAILED., THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
DURING A CHECK, THE R3 DOOR M33401 BATTERY PACK CAPACITY CHECK FAILED. THE BATTERY PACK REPLACED AND TESTED NORMAL IAW AMM 33-51-06.
AT IDLE DESCENT WITH HIGH PRESSURE VALVES OPEN, A NOXIOUS OILY ODOR. REPLACE THE NR 1 ENGINE IAW MM 71-00-02.
CABIN COMPLAINS OF HYDRAULIC FUME SMELL SEVERAL PEOPLE NAUSEOUS. OIL FOUND IN HPC STAGES 6 AND 7. REQUIRES ENG CHANGE. REPLACED NR 1 ENGINE PER AMM 72-00-00.
DIRTY SOCK ODOR WHEN ACFT REACHED CRUISE, AFTER LEVEL OFF IN FLIGHT DECK & FIRST REAR CABIN, THEN IN FIRST CLASS, HAZE IN FLIGHT DECK WAS INCREASING. SHUT OFF THE UPPER RECIRC FAN & ODOR SEEMED TO INTENSIFY, THE UPPER WAS SELECTED BACK ON THEN THE LOWER WAS SHUT OFF. FOUND PROBLEM ON NR 1 ENG, HIGH OIL CONSUMPTION. TO BE REPLACED IAW LR1566.
DIRTY SOCK ODOR WHEN ACFT REACHED CRUISE, AFTER LEVEL OFF, IN FLIGHT DECK & FIRST REAR CABIN, THEN IN FIRST CLASS. HAZE IN FLIGHT DECK WAS INCREASING. NR 1 ENG HAS OIL IN THE TAIL PIPE & 9 QTS OF OIL ADDED, HIGH OIL CONSUMPTION. REPLACED NR 1 ENG IAW AMM 71-00-02 PG 401.
COCKPIT EMER LIGHT SWITCH ARMING WIRE BROKEN OFF SWITCH GUARD. REPLACED SWITCH GUARD. ARMING FUNCTION OPERATIONS OK.
EXIT LIGHT LENS NOT SECURE, FALLS OFF, LOCATION DOOR 3L. REPLACED EMER LIGHT ASSEMBLY, OPERATIONS NORMAL.
EMERGENCY LIGHT IN AFT CABIN ON, WITH OVERHEAD SWITCH IN OFF POSITION. FOUND RECESSED PIN AT P10 3 PANEL RECEPTACLE D1373J PIN 10 WDM 33-51-12. REINSERTED PIN INTO RECEPTACLE. ALSO FOUND EMER LIGHT CHARGER MODULE M33405 INOPERATIVE. REPLACED CHARGER & BATTERY. EMER LIGHT OPERATION NORMAL THROUGHOUT CABIN. AFT CABIN EMER LIGHTS OFF, WITH OVERHEAD SWITCH IN OFF POSITION. EMER LIGHT SYS CHECKED NORMAL.
SEAT 34G EEL INOPERATIVE. SECURED EEL SEAT LAMP. OPERATIONS CHECKED GOOD.
DOOR 4L & DOOR 4R EMER EXIT SIGNS REMAIN ILLUMINATED AFTER SELECTING EMER LIGHT SWITCH TO THE OFF POSITION. SEATED CONNECTOR TO EMER LIGHT POWER SUPPLY FOR DOOR 4L & 4R, RESET EMER LIGHT CB DOOR 4L & 4R ON P 11 PANEL. ACCOMPLISHED SUCCESSFUL TEST OF THE EMER LIGHTS IAW AMM 33-51-00-501.
EMERGENCY EXIT LIGHTS CAME ON AFTER LANDING & FAILED TO EXTINGUISH, ROW 44 LT & RT AISLES, BACK TO 4L & 4R. CEILING & DOOR AREA LIGHTS. ACCOMPLISHED EMER LIGHT TEST IAW MM 33-51-00. UNABLE TO DUPLICATE FAULT.
STRINGER CORROSION WAS FOUND AT STRINGER 44L BETWEEN STATION 1916 & 1958. REPAIRED IAW SRM 51-70-11 REV 67 & ECRA 5330-05162.
ON ARRIVAL, OVERHEAD EMER LIGHTS BY 4L & 4R STAY ON WITH SWITCH OFF. REPLACED DR 5L EMER POWER SUPPLY FUSE F2, RELAMP AISLE CEILING LIGHT ABOVE 50ABC & RELAMP DR 5L DROP CEILING EMER LIGHT.
ON ARRIVAL EMER LIGHT AT DOOR 4L & 4R AREA ON. REPLACED EMER LIGHT BATTERY FWD ABOVE DOOR 4R. EMER LIGHT BACK TO NORMAL. CHECKED OK. BATTERY REPLACED & TESTED IAW AMM 33-51-06.
EMERGENCY EXIT LIGHTING AT SEAT ROWS 16 - 21 INOPERATIVE. INSTALLED CABLE ASSEMBLY FROM SEAT 16 -17 & 34 - 35 IAW AMM23-34-04. OPERATIONS CHECK TEST OF EMER LIGHTS FOR SEAT ROWS 16 - 21 IAW AMM33-51-00-710-801. OPERATIONS TESTED GOOD PN 286U0001-1005.
EEL FLOOR PROXIMITY LIGHTS BURN DIMLY BETWEEN ROWS 22 & 33. TRIED A NEW POWER SUPPLY, NO HELP. CHARGED BATTERY IN PLACE, LIGHTS ARE SERVICEABLE.
AFTER REPLACEMENT OF LT NR 1 WINDSHIELD IAW LM1122 & COMPLETING COA 209881 WINDOW HEAT WIRING INSTALLATION, MAT TEST FOR LT WINDOW HEAT FAILED WITH LATCHED MX MSG 30-24011.
AFTER REPLACEMENT OF LT NR 1 WINDSHIELD & COMPLETING COA 209881, WINDOW HEAT WIRING INSTALLATION, MAT TEST FOR LT WINDOW HEAT FAILED WITH LATCHED MX MSG 30-24011. RESEATED PINS J15 & J13 IAW WD30-41-11. MSG CLEARED MAT TEST PASSED.
OXYGEN MASKS DROPPED AT 1JH. INSPECTED & REPACKED O2 MASKS IAW AMM 35-21-13. OK FOR SERVICE.
ONE, BUT NOT BOTH OF THE TWO RT PACK FLOW CONTROL VLVS, FCV, ARE NOT IN THE COMMANDED POSITION. STATUS MSG 2124002 LATCHED CL MODE.
REVERSER INTERLOCK RT REVERSER THRUST LEVER INTERLOCK FAILURE. CYCLED RT REVERSER, OPERATIONS NORMAL, NO MSGS.
FLIGHT ATTENDANT REPORTS CHEMICAL OR ELEC SMELL ROW 22 - 26 CDEF, NO SMOKE. INSPECTED 22 - 26 CDEF UNDERSEAT HARNESS & SEAT BOXES. CHECKED ALL READING LIGHT & CALL LIGHTS. BOTH LOWER RECIRCULATING FANS OPERATIONS NORMAL, NO DEFECTS NOTED. OK FOR SERVICE IAW AMM 05-51-50.
OIL QTY WENT TO ZERO APPROXIMATELY AT 1529Z. TEMP PRESS OK. IT WAS ENG 2 WITH OIL LOSS. FOUND AIR & OIL COOLER B CRACKED. WILL REPLACE COOLER PARTS ON FLT 73 ETA 1825 HRS.
FUSELAGE EXTERIOR SKIN DENT AT STATION 2100 RT STRINGER 29R - 30R. DENT OUT OF LIMITS IAW 53-00-01. THIS EXT DOUBLER REPAIR 7 IS A CAT B REPAIR IN ZONE B. SUBSEQUENT INSPECTIONS ARE NECESSARY FOR REPAIR 7 IAW PARA 6 REPAIR 7 PAGE 216, TABLE 204. INTERNAL HFEC RECOMMENDED IAW NDT. IAW NDT PART 6, 53-00-06 & DETAILED VISUAL INSPECTION PARTIAL. DOUBLER REPAIR AT STATION 2087 TO 2108. STRINGER 29R - 30R REQ RE INSPECTION EVERY 16K CYCLE THRESHOLD AT TIME OF REPAIR. CURRENT PTC=13244. INITIAL CRITICAL ROWS OF FASTENERS ARE ZERO TIMED. MF4149 ADDED TO MONITOR. HOLES 0 TIMED THRESHOLD IS 30000 CYC FROM TIME REPAIR WAS INSTALLED WITH REPEAT INSP EVERY 16000 CYC THEREAFTER. INSPECTION IAW SRM 53-00-01 RPR 7 TABLE 204. THIS IS A PERM REPAIR PROVIDED REPEAT INSPECTION ON MF4149 ARE ACCOMPLISHED. MOVED CF548 TO CF9 STATUS & REMOVED HARD TIME LIMITS.
FUSELAGE EXTERIOR SKIN DENT AT STATION 2100 RT STRINGER 29R - 30R. DENT OUT OF LIMITS IAW SRM 53-00-01 FIG 102 DET E. THIS EXT DOUBLER REPAIR 7 IS A CAT B REPAIR IN ZONE B. SUBSEQUENT INSPECTIONS ARE NECESSARY FOR REPAIR 7 IAW PARA 6 REPAIR 7 PAGE 216. TABLE 204. INTERNAL HFEC RECOMMENDED IAW NDT. DOUBLER REPAIR AT STATION 2087 TO 2108. STRINGER 29R - 30R REQUIRES REPAIR INSPECTION EVERY 16K CYCLES THRESHOLD AT TIME OF REPAIR. CURRENT PTC=13244, INITIAL CRITICAL ROWS OF FASTENERS ARE ZERO TIMED.
MOMENTARY HOT METALLIC SMELL REPORTED BY DOOR 3R, SMELL DISSIPATED. VERIFIED NO SMOKE WAS PRESENT. UNABLE TO DETECT SMELL ON GND OR EVIDENCE OF POSSIBLE CAUSE OF MOMENTARY SMELL AS REPORTED.
1F EMERGENCY PATH LIGHT INOPERATIVE & DETACHED. SEAT 1F AFT PATH ILLUMINATED LIGHT INOPERATIVE, SEAT MOUNTED WHITE PATH ILLUMINATED LIGHT. REPLACED EMERGENCY EXIT LIGHT STRIP, OPERATIONS C CHECKED OK.
INOPERATIVE ON FIRE TEST. NO TEST IN PROGRESS OR TEST PASS OR FAIL MESSAGE DURING TESTING. FOUND S3 FIRE TEST SWITCH BAD. REPLACED SWITCH, TESTED NORMAL.
1F EMERGENCY LIGHT STRIP HANGING OFF. SECURED STRIP, OPERATIONS OKAY.
LT WING FUELING VLVS WILL NOT OPEN. RESET CB'S NO HELP. MANUALLY OPENED FILL VLVS. AIRCRAFT WILL NOT ACCEPT FUEL, CHECKED FOR VOLTAGE AT LT WING FUELING VLV V28107 PIN 2. HAVE 28V AT CONNECTOR & GNDS AT PINS 1,3 & 4, BAD FUELING VLV. VLV ON ORDER PCN 646-0067.
CAPTAIN'S NR 2 & 3 WINDOWS BADLY SCRATCHED VISIBILITY IMPAIRED. ACCOMPLISHED INSPECTION OF WINDOWS & FOUND WINDOW CRAZING. POLISHED WINDOWS & IS ACCEPTABLE TO OUTBOUND CREW NO SCRATCHES. THE VISIBILITY THROUGH THE WINDOW IS ACCEPTABLE & THE SCRATCHES ARE WITHIN MX LIMITS.
1ST OBSERVER WILL NOT RECEIVE AUDIO. REPLACED BAD MINITEL, OPERATIONS OKAY.
RT PACK Y-DUCT AFT OF OZONE CONVERTER CRACKED. IAW IPC 21-73-01-001 ITEM.65 PN 213W2120-9 PCN 120-2209. REPLACED DUCT, NO LEAKS NOTED.
FUEL PUMP LT FWD EICAS MESSAGE. REPLACED LT FWD BOOST PUMP PRESSURE SW, OPERATIONS CHECKED OKAY.
RT LANDING LIGHT APPEARS TO BE VERY DIM. MAY BE INCORRECT BULB. SPLICED IN NEW WIRE APPROXIMATELY 10 INCHES FROM LAMP L33215 WIRE W8211-003-12 IAW SWP 20-10-13, & NEW RING TERMINAL IAW SWP 20-30-11. LIGHT OPERATIONS CHECKED NORMAL IAW WD 33-42-11.
MAIN BATTERY HAS BEEN CHARGING 10 AMP FOR 4.5 HRS. R & R MAIN BATTERY CHARGER IAW MM. ALL OPERATIONS NORMAL BORROWED PART SUB CAL ME 25-2431-9-0007 TT 1633772 MR NR OFF 24310 DASH 147.
FLAP HANDLE STIFF, STICKS WHEN EXTENDING & RETRACTING FLAPS. LUBE FLAP HANDLE, OPERATIONS CHECKED OK.
NR 1 ENG WEEP TUBE IS CLOGGED HAS NUT STUCK IN END OF TUBE. DURING ROUTINE INSPECTION IAW EC4141-1 FOUND TUBE BLOCKED. IAW MM 72-00-88 PG628 STEP 4 TUBE TO BE CLEARED WITHIN 100 CYCLES OR ENGINE REPLACED.
CSCP-CACP ZONE TEMPERATURE DISPLAY FAULT MESSAGE SHOWS DR-1L ATTENDANT PANEL. ZONE C INVALID DATA DISPLAYED, DOOR 1 CSCP-CACP. FOUND ZONE 3 TEMPERATURE INVALID, CLEANED TEMPERATURE SENSOR & RAN TEMPERATURE CONTROL VALVE TEST. TEMPERATURE RETURNED.
LT ESC STATUS MESSAGE. REPLACED LT ESC CARD.
TROUBLESHOOTING SMC22, REPLACED BOTH OPIC AI & A2 CARDS BUT NO HELP. REINSTALLED BOTH INITIAL CARDS, REPLACED THE OPBC CONTROLLER, ALSO NO HELP. DASH NUMBERS NEED TO BE DOCUMENTED IN MRDATA AFTER REPAIR. MR23931 OFF-110 ON-63. PERFORMED MAT TEST AFTER OPBC REPLACED & LT OPAS MESSAGE DISPLAYED. AFTER TIME MESSAGE LT OPAS CLEARED. ACCOMPLISHED MAT TEST LT OPAS. TEST PASSED NO MAINT OR STATUS MESSAGE DISPLAYED.
MAIN BATTERY CHARGING AT 10 AMPS-28VDC INDICATED. MAIN BATTERY NOT CHARGING MORE ON GROUND. REPLACED BATTERY CHARGER IAW MM 24-31-02 AS PRECAUTIONARY.
LOUD SQUEAL AT L2 DOOR, INSPECTED DOOR & FRAME. LOWER DOOR FRAME ABOVE SCUFF PLATES REQUIRES FAIRING COMPOUND ON FORE & AFT SCUFF PLATE EDGES IAW MM. APPLIED FAIRING COMPOUND FORE & AFT AT SCUFF PLATE EDGES PER MM.
MAIN BATTERY CHARGE IS 11 AMPS 28 VOLTS ENTIRE FLIGHT. REPLACED MAIN BATTERY PER AMM, MAIN BATTERY CHECKED NORMAL.
HIGH PRESSURE WHINE AT L2 DOOR. CLEANED, REWORKED & APPLIED SILICON RUBBER ADHESIVE TO AFT LOWER CORNER OF SEAL.
L2 DOOR LOWER, HIGH PITCHED NOISE. CLEANED SEALS & APPLIED SEALANT TO TRANSITION AFT LOWER DOOR SEAL IAW MM 52-09-01. LEAK CHECKED GOOD.
RIGHT BLEED EICAS ALONG WITH NO RT BLEED DUCT PRESSURE. EVEN THROTTLE BUMP STILL NO DUCT PRESSURE. RETURN TO GATE. HP SHUTOFF VALVE FAILED CLOSED. FOUND HPSOV SENSE LINE AT CONTROLLER VERY LOOSE. TIGHTENED. REPLACED HPSOV AND HPSOV CONTROLLER, PRECAUTIONARY, IAW MM 36-11-07 AND MM 36-11-08. RAN ENGINE, BLEED VALVE OPS OK AND PNEU INDICATIONS NORMAL.
AFTER ACFT TOWING, OPIC LA1, OPIC LA2 DISPLAYED ON EICAS. REPLACED A1 AND A2 CARD AND OPIC IAW MM. OPS CHECKED GOOD.
MAIN BATTERY DISCHARGED. REPLACED MAIN BATTERY, CHECKED OK. FOV BATT EICAS MESSAGE CAME ON AFTER MAIN BATTERY WAS REPLACED. CHARGED BATTERY, MESSAGE CLEARED AND NO FAULTS NOTED AFTER RECHARGE.
EMERGENCY EXIT LIGHT CAPTAIN`S SIDE COCKPIT CONSOLE CAME LOOSE. SECURED LOOSE PANEL, OK.
PACK FCV R STATUS MESSAGE. IAW FIM 21-51 TASK 816, R & R COMPRESSOR DISCHARGE TEMP SENSOR. PERFORMED GROUND TEST 21 CABINS TEMP CONTROL SYS OPS TEST RT SYS ON, TEST PASSED, NO FAULTS OR MSG AT THIS TIME,
TRIM AIR PRSOV L LT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE (PRSOV) FAILED. REPLACED LT TRIM AIR PRSOV, OPS CHECKED GOOD.
EXIT SIGN LENS ABOVE 2L DETATCHED. SECURED LENS ASSY.
STATUS MESSAGE, DC STANDBY ELECTRICAL POWER 24 13037. FOUND K24013 RELAY BAD, REPLACED OPS CHECKED GOOD. MESSAGE CLEARED.
CAPTAIN`S AUDIO SELECTOR PANEL CANNOT CHANGE MICROPHONE SELECTION. REPLACED AUDIO SELECTOR PANEL. OPS OK.
NR 1 ENG LPT CABLE BROKEN AT VALVE 3:00. SUP: R & R IAW AMM, OPS CK GOOD.
STATUS MESSAGE ON DEPARTURE CHECK, FUEL QTY CHANNEL. NO STATUS MESSAGES, NO EXISTING FAULTS. PROCESSOR NOT REPLACED SINCE NO HARD FAULTS ARE PRESENT.
PRIOR TO DEPARTURE, APU AUTO SHUTDOWN TWICE. REPLACED APU OIL TEMP SENSOR PER MM, OPS CHECKED OK, APU MESSAGE CLEARED, MAT MESSAGE NOT ACTIVE. APU OIL FULL. ACFT RETURN TO BLOCKS SECOND TIME. SAME PROBLEM HIGH OIL TEMP DETECTED BY APUC. FOUND 1 X 1.5 HOLE IN LEFT SIDE BURNER SECTION. INSPECTED AREA, NO APPARENT DAMAGE TO APU COMPT. REPLACED APU, OPS CHECKED GOOD. NO LEAKS NOTED.
LEFT HYDRAULIC SYSTEM SHOWED 60 PERCENT ON TD. FOUND HYD FLUID LEAKING FROM RUDDER MID PCU DYNAMIC SEAL MORE THAN NORMAL LIMIT BUT LESS THAN DISPATCH LIMIT PER AMM, WITH SYSTEM PRESSURIZED. LEFT HYD SYSTEM SERVICED TO FULL. ACFT CONTINUES TO SERVICE MAXIMUM 75 FLT HRS. CURRENT PTT IS 70427. REMOVED AND REPLACED LEFT SYSTEM ACTUATOR PER AMM
F/C LAV LEAKING, RTFL. REPLACED TOILET ASSY PER AMM. HOT WATER HEATER TURNED ON. NEED TO CHECK BELOW DECK TO CONFIRM WATER FROM LAV DID NOT LEAK BELOW DECK. NO EVIDENCE OF WATER SEEPAGE INTO R&E COMPT.
RIGHT PACK INLET DUCT, PARTIALLY MISSING SEAL APPROX 3 FEET FROM PACK INLET. REPLACED SEAL, OPS CHECKED OKAY.
ELECTRIC STANDBY SYSTEM STATUS MSG DISPLAYED. FOUND MSG 24-13037 T-S & REPLACED DC TIE RELAY K24013 IN P210 PANEL PER MM AND PERFORMED DC-STBY PWR SYSTEM OP TEST PER TASK 24-30-00-700-801. DC- STBY PWR TEST PASSED. FOUND NO FAULTS.
RIGHT BRAKE SHUTTLE VALVE LEAKING. REPLACED O-RING MOST FORWARD LOWER UNION :RIGHT ANTI-SKID SHUTTLE VALVE. OPERATED SYSTEM, NO LEAK.
EMERGENCY EXIT LIGHT IS INOP AT SEAT 31G. FOUND WIRE DISCONNECTED. RECONNECTED WIRE, OPS CHECKED GOOD. EMERGENCY LIGHTS OPS CHECK GOOD.
EMERGENCY EXIT LIGHTS ARE INOP AT SEAT 3F. REPLACED LIGHT STRIPS AT SEAT 3F, OPS CHECKED GOOD. EMERGENCY LIGHTS TEST GOOD, REF 09-10-05.
FUEL QTY CHANNEL MESSAGE. RESEATED FUEL QUANTITY PROCESSOR, OPS CHECKED.
MAIN BATTERY WEAK STATUS MESSAGE DISPLAYED. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM.
WATER POURED IN 1ST CLASS GALLEY DRAIN SPILLING OUT OF 1ST CLASS LAVATORY SINKS AND RUNNING DOWN THRU E/E COMPARTMENT. REPLACED FWD GRAY WATER DRAIN RESTRICTER VALVE PER MM.
DOOR 4 LEFT EPAS BATTERY INOP. EPAS BAT IN ARMED POSITION WITH GREEN LIGHT FLASHING REF GROUP 31. REPLACED INOP BATTERY ON EPAS IN REF WITH AMM. ACCOMPLISH RII INSPECTION OF AMIS ITEM 0902032.
APU OIL CONSUMPTION ABOVE LIMIT. HIGH OIL COMSUMPTION - FAULT ISOLATION. STARTED ALL OF A SUDDEN 03JUN. OIL IS DIFFICULT TO SEE IF NOT COKED. CHECK ALL LINES & "O" RING CONNECTIONS. ONE SUCH HOC WAS "O" RINGS ON THERMAL BYPASS VALVE. REPAIR OR REPLACE AS NEED & INCL FINDINGS IN ACP W-U. RDF-T :CHECK APU PER FIM 49-20-818 FOUND NO LEAK OR SMOKE FROM TAIL PIPE BUT CHECK MID BRG AND FOUND CHIPS WILL NEED APU CHANGE. REPLACED APU.
CAPTAIN`S WINDSHIELD WIPER BLADE NEEDS REPLACING. REPLACED WIPER BLADE PER MM, OPS CHECKED GOOD.
FMC L STATUS FAULT MESSAGE DISPLAYED. RESET L AIMS CABINET REF MM AND OP CHECKED. OP CHECKED GOOD ON GROUND CHECKS.
NR 1 PYLON HEAT SHIELD NR 2 AND NR 3 CASTINGS WORN AND GAP COVER STRIPS WORN. HEAT SHIELDS WORN GREATER THAN .005". NR 1 ENGINE HEAT SHIELDS WORN. GATORBACK REMOVED. REPLACING BLAN KETS ON HEAT SHIELDS 1,2,3 AND 4. REF 1123 AND REF MM. INSTALLED NR 1 ENGINE HEAT SHIELDS SERVICEABLE UNITS. REPLACED GAP STRIPS,
DOOR 1L OUTSIDE DOOR METAL THRESHOLD DAMAGED, 3 INCH BY 3 INCH PIECE BROKEN OFF, AFT CORNER AREA. REPLACED SCUFF PLATE. SCUFF PLATE IS SECURED AND SEALED REF MM 53-11-01 AND METHOD 3.
C2 PUMP PRESS OUT-RANGE AHM IS HITTING ON ALL LEGS FOR MSG 29-10570, ACMP C2 OUTPUT PRESSURE IS OUT OF RANGE. THIS IS ONE OF 2 A-C IN FLEET WITH MSG AND CAN LEAD TO EXCESSIVE CYCLING OF ADU AND CATASTROPHIC FAILURE. REF FIM 29-11, TASK 898. INITIATE T/S IN PARA C AND AS A MINIMUM CK AC C-2 PUMP CONNECTOR FOR CORROSION, ARCING A CONDITION. CHECK FILTER DELTA P HAS NOT POPPED AND SWAP HYDUM CARD WITH C-1. MAY CONSIDER REPLACING PRESSURE XDUCER M29317. PCN 566-0603. DO NOT RPL THE ACMP UNLESS THERE ARE POSITIVE FINDINGS. FOUND PRESSURE FOR ACMP 2 HIGH 3340 PSI TEMP OK. RPL'D PRESS TRANSDUCER. M29317 AFTER REPLACEMENT OF PRESS TRANS PRESS WITHIN LIMITS. CHK'D ALL CONNECTORS FOUND OKAY.
LEFT ENGINE ANTI ICE VALVE DOES NOT OPEN WHEN SELECTED, ON GROUND. REPLACED ENGINE ANTI-ICE VALVE PER MM. ACCOMPLISHED ENGINE RUN PER JRH AND ACCOMPLISHED MAT TEST OF ENGINE ANTI-ICE VALVE. TEST PASSED AND STATUS MESSAGE CLEARED, INDICATION ON EICAS NORMAL.
UNDERSEAT UNIT AT 22CDE IS CAUSING A BURNING PLASTIC SMELL IN CABIN. FLIGHT ATTENDANTS TURNED OFF SEAT POWER AT CACP, SMELL DISSIPATED. MECHANIC ON BOARD VERIFIED THAT SMELL WAS COMING FROM VIDEO DISTRIBUTION UNIT UNDER SEAT. WILL ALSO NEED TO CHECK ALL OTHER VDU'S IN AREA OF ROWS 22-24 FOR POSSIBLE SOURCE. SOURCE OF ODOR SEAT 22D SEAT ELECTRONICS UNIT. ALSO FOUND HARNESS BACK SHELL AT 22D SEU J1 (UNRELATED). REPLACED 22D SEU AND SEAT-SEAT CABLE FROM 21D TO 22D. SYSTEM CHECKS NORMAL, NO ODOR.
PANEL DAMAGED TOP OF VERT FIN AT TRAILING EDGE FIRST PANEL FWD OF RUDDER LT SIDE. PANEL HAS INTERIM REPAIR INSTALLED. REF IPC55-36-01-02 AREA A ITEM 35 THIS IS A VERTICAL STABILIZER TO RUDDER "SEAL". THIS SEAL (PANEL) WAS DAMAGED IN FLIGHT DUE TO HARDWARE WHICH WAS NOT INSTALLED. REPAIR BY TRIMMING PANEL FROM UPPER ANGLED EDGE TO THE TRAILING EDGE AREA. REPLACED GAP SEAL PANEL.
NR 1 NACELLE INBD HYD LINES TO PYLON INSULATION BLANKET DETERIORATED. REMOVED AND INSTALLED NEW INSULATION BLANKET.
DURING RIGHT AIMS SYSTEM TEST, FOUND IOM M009 HAS AN ARINC 629 FAULT ON FLIGHT CONTROLS ARINC 629 BUS (LEFT). MAINTENANCE MESSAGE 31-58102. RELOADED IOM OPS SOFTWARE, NO HELP. NEEDS IOM M009 IN RIGHT AIMS. REPLACED RIGHT AIMS CABINET M9 MODULE, CHECKS OKAY.
DOOR 2R GIRT BAR SUPPORT BRACKET BROKEN. DOOR 2R ESCAPE SLIDE REMOVED PER MM. TWO GIRT BAR SUPPORT BRACKET BROKEN. REMOVED DOOR 2RT AFT GIRT BAR SUPPORT DUE TO IT BEING BROKEN. REPLACED GIRT BAR SUPPORT. REPLACED AFT GIRT BAR BRACKET DOOR 2R. RE-INSTALLED DOOR 2R SLIDE.
AFT EMERGENCY LIGHT AT SEAT 2E INOP. REPLACED EMERGENCY LIGHT. LIGHT OP CHECKS OK.
PFC CONTROL LANES DISPLAYED. REPLACED LEFT O/B PCU AND CONFIDENCE TEST AND RIG CHECK REF MM. COMPLETED INSP OF PCU.
DOOR 1L WHISTLING. LHRMM ON AC PULLING UP OLD SCUFFPLATE. TRIMMED EXCESS SEALANT IN DOOR SILL AREA, CLEANED AND LUBED SEAL. NO OTHER DEFECTS NOTED. REPLACED 1L DOOR SCUFF PLATE AS PER MM. PRESSURE RUN TO BE ACP AFTER FITTING OF DOOR SCUFF PLATE. RUN ACCOMPLISHED AS PER MM. RUN RESULTS WELL WITHIN THE SATISFACTORY ZONE. NO LEAKS OR WHISTLES NOTED DURING LEAKAGE RATE ANALYSIS.
ELEC GEN DRIVE L LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). ADVISORY MSG-2431551 LATCHD ER MODE. REPLACED IDG IAW MM. OPS NORMAL.
ELEC GEN SYS L IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (L) FREQUENCY IS LOW. DB- GENERATOR CONTROL UNIT (L) MSG-2431631 LATCHED CL MODE. FOUND IDG OVER SERVICED 3 QUARTS. REPLACED IDG PER AMM. OPS AND INDICATIONS NORMAL NOW.
CAPTAINS NR 1 WINDOW OUT OF TOLERANCE. REMOVED CAPTAINS NR 1 WINDOW, REPLACED CAPTAINS NR 1 WINDSHIELD.
RIGHT ENGINE MOUNT FLUID LEAK FOUND ON WALKAROUND. REPLACED HYD SUPPLY LINE ELBOW AT RIGHT ENGINE PYLON EDP CASE DRAIN MODULE. LEAK CHECK NORMAL, RIGHT SYSTEM SERVICED TO FULL.
FOUND DAMAGED,OPEN,BURNT WIRE HARNESS IN BAY STA 1642 TO STA 1664, RBL24 UNDER FLOORBOARDS. WIRES FOR POWER DRIVE UNITS. ORDERED REPLACEMENT WIRE AND STARTED MARKING, ID BROKEN LEADS. (AOG Y3604 3 COLOR CONDUCTOR. 561-1247). ID WIRES FOR R,B, AND Y LEADS REF W5081- 3009 (3001, 3005) AND MARKED. RPR'D WIRES INSTLD ENVRMNTL SPLICES REF GNMM. PROVIDED CLEARANCE OFF FLOOR. REF WDM. ALL PIT LOADING CHECKS OKAY.
CAPTAIN'S O2 MASK HAS BROKEN RED CLIP. CAPTAIN'S O2 MASK SWAPPED WITH O2 MASK OBSERVER SEAT IAW AMM. REPLACED MASK.
OPBC L OVERHEAD PANEL BUS CONTROLLER (OPBC) FAULT. STATUS MSG-2348801 ACTIVE MT HARD. REPLACED THE LEFT OPBC PER MM, ACCOMPLISHED MAT TEST, TESTED NORMAL, NO FAULTS.
NR 2 NACELLE AFT STRUT FAIRING LOWER HEAT SHIELD SEAL RETAINER HAS 6 LOOSE ATTACHMENT FASTENER. ACCOMPLISHED INTERIM REPAIR REF MT 54-UA1. RE-INSPECT EVERY 3 SERVICE AND PERMANENT REPAIR AT C CHECK. OK TO CF9 PER OPBLM.INTERIM FASTENERS ARE 3,5, 9,11,15, AND 18. ADDITIONAL FASTNERS REPLACED AT LOCATIONS 4, 6, 7, 8, 10, 14, 19 PER MT AND EVA 80492. REQS RECHECK AT EVERY 3SV UNTIL PERMANENT REPAIR AT NEXT C#2 CK. REPLACED FIRESEAL, HEATSHIELD AND INSTALLED GATORBACKS.
POSSIBLE ELECTRICAL ODOR ABOVE LAV 133. INSPECTED AREA AROUND LAV AT DOOR 3 LT AND NO OBVIOUS INDICATIONS OF ELECTRICAL ODOR, CREW REPORT ODOR CLEARED DURING TAXI.
ANTI-ICE ENG L LEFT ENGINE ANTI-ICE (EAI) VALVE FAILURE TO THE CLOSED POSITION OR LEFT EAI CONTROL CARD FAILURE. REPLACED LT ENG EAI VALVE CONTROLLER IAW MM. ACCOMPLISHED EAI TEST WITH ENG RUNNING IAW MM. ENGINE ANTI-ICE, OPS CHECKS NORMAL.
ENG IGNITOR L2 LT ENGINE FAILED TO IGNITE USING IGNITOR 2. REPEAT WRITEUP MSG-7461501 INACTIVE MODE. LT ENG IGNITOR 2 INOP. REPLACED LT ENGINE NR 2 IGNITER PLUG IAW AMM. REPLACED IGNITER LEAD AND EXCITER BOX IAW AMM. PERFORMED IGNITER PLUG TEST.
ENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MSG-7461501 INACTIVE ES MODE. REPLACED NR 1 ENG RELAY UNIT PER MM. RAN ENG TWO TIMES WITH NO FAULTS. TESTED ERU INSTALLATION PER MM. ALL CHECKS GOOD.
ENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MESSAGE-7461501 INACTIVE ES MODE. REPLACED EXCITER MODULE, IGNITION LEAD AND IGNITION PLUG.
METAL ON CHIP DETECTORS AND FOUND IN MAIN OIL FILTER. REPLACED ENGINE.
ENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITOR 2. STATUS MESSAGE-7461501 INACTIVE ES MODE. REPLACED LEFT ENGINE NR 2 EXCITER BOX. AUDIBLE OPS CHECKS GOOD. 4 ENGINE STARTS AND NO MESSAGE.
NR 2 ENGINE FOUND METAL CHIPS AND FLAKES ON OIL TANK CHIP DETECTOR.
NR 1 ENGINE NOSE COWL ELECTRICAL CONNECTOR AT 11 O'CLOCK POSITION IS INCORRECTLY WIRED. CONNECTOR D71018J. WIRED CONNECTOR D71018J PER HOOK UP CHART AND WD 78-31-11, OPS NORMAL.
APU CONT STATUS MESSAGE. REPLACED APU CONTROLLER, TESTS OKAY. MESSAGE CLEARED.
APU AUTO SHUTDOWN ON START. UNABLE TO GET APU BACK ON LINE. REPLACED APU. OPS GOOD.
RT PACK, CHECK BYPASS FAN VALVE HINGE POINTS WORN. REPLACED CHECK VALVE.
LEFT PACK RAM AIR PLENUM LOWER ACCESS PANEL FASTENER PULLED THRU. REMOVED PLENUM LOWER ACCESS PANEL. INSTALLED FIBERGLASS REPAIR TO DAMAGED AREA. INSTALLED LOWER ACCESS PANEL
UPPER TORQUE MOTOR NOT IN THE COMMANDED POSITION. THIS FAILURE WILL LEAD TO SERVICE DISRUPTIONS IF LT UNCORRECTED. CHECKING ASSOCIATED WIRE AND CONNECTOR FOR DEFECTS. NONE NOTED. REPLACED THE RT PACK UPPER FCV, V21512. REPLACED UPPER FLOW CONTROL AND SHUTOFF VALVE. OPS NORMAL.
RIGHT PACK HEAT EXCHANGER HAS 2 CRACKS ON UPPER AND LOWER SURFACES APPROX 5 INCHES IN LENGTH EACH. LH HEAT EXCHANGER HAS A 19 INCH CRACK AT THE 6:00 O' CLOCK POSITION. SUPPLEMENTAL DATA UPDATE REMOVED & REPLACED RH & LH PACK HEAT EXCHANGERS. ACP'D RH & LH PACK HEAT EXCHANGERS LEAK CHECKED AND INSTALLATION TESTED. NO LEAKS NOTED.
RT PACK RAM AIR INLET PLENUM LOWER ACCESS PANEL BLOWN APART, WITH VARIOUS CRACKS IN PLENUM. REMOVED RT PACK PLENUM. BEGAN REPAIRS. REPAIRED PANEL HOLES AND CRACKS IN PLENUM.
BOTTLE 2A CARGO, BOTTLE 2B CARGO, AND BOTTLE 2C CARGO STATUS MESSAGES DISPLAYED ON LOWER EICAS. ACCOMPLISHED GROUND TEST 26 CARGO SQUIB TEST, TEST FAIL. CIRCUIT OPEN. REF MAT MAINT MSG FAULTS 26 -40100, 26-40110, 26-40120, REPLACED ELMS P310 I-O CARD M24406A7, FILTER CARD M24406A17 SWAPPED, SIG COND CARD M24410 ASSY REPLACED, NO HELP, ORIGINAL I-O CARD BACK IN, ALL NO HELP. NEXT STEP WIRING CKS REF FIM26-23TSK808. WIRING RANG GOOD FROM FIRE EXT BOTTLES 2A,B,C TO D31023P REF FIM26-23 PG213, ALL RESECURED. REPLACED I-O CARD M24406A6 MM, RELOADED ELMS P310 SOFTWARE, NO HELP, GROUND TEST FAILS & STATUS MESSAGES LATCHED, SUSPECT SOFTWARE CONFIGURATION. REPLACED & AOG 3 EACH MR26240 BOTTLES. OPS CHECKED OKAY.
CMC NR 1 MANAGEMENT SYSTEM (ELMS) P110. HIT 3 TIMES IN HISTORY. REPLACED CARD M24400A2 IN P110 PANEL.
RN 2 ENG. OUTER KEVLAR CONTAINMANT RING DAMAGED AT APPOX. 1 O'CLOCK POS. (UNDER RH FAN COWL). REPAIRED REF MM. ACCOMPLISHED TEMPORARY REPAIR OF OUTER ENVIRONMENTAL LAYER. TEMPORARY 50 HOUR FLYBACK REPAIR. DAMAGE WAS A CRACK AND PARTIAL TEAR APPRX 10 TO 12 INCHES THROUGH OUTER LAYER ONLY. DUE TO LENGTH OF CRACK, NEED CLOTH-REINFORCED EPOXY REPAIR PER EVA-73977. COVER WITH FIBERGLASS CLOTH PCN 833-0218 THAT EXTENDS AT LEAST 1 INCH BEYOND DEFECT ALL AROUND. APPLY 2 COATS OF EPOXY RESIN 840-0513 TO CLOTH WITH CURE TIME IN BETWEEN. RECOMMEND ORDER ENOUGH 840-0513 TO COVER APPROX 14X3 INCH CLOTH 2X. REPAIRED DAMAGED CONTAINMENT RING. REF EVA, UA-EVA-73977.
EXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2 LT. RELAMPED.
EXTERIOR EMERGENCY EXIT LIGHT LENS CRACKED AT DOOR 1 RT. INSTALLED NEW LENS ASSY.
EXTERIOR EMERGENCY EXIT LIGHT INOP. AT DOOR 1 RIGHT. RELAMPED.
EXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 3 LT RELAMPED.
EICAS HAS STATUS MSG FLAP-SLAT CONTROL 1. DURING T-S EXISTING FAULT HAS HIGH LIFT SYS (FSEU 1 PROGRAM PINS ARE INCORRECT) . CONFIG SHOWS A-P MODEL INVALID. REPLACED FSEU 1. SYS CONFIG SAME AS FSEU2. TEST PASSED AND EICAS CLEARED.
FLAP SLAT FSEU NR 2 HAS NO OUTPUT ON SYS ARINC 629 BUS (RT) STATUS MESSAGE FLAP-SLAT CONTROL NR 2. CYCLED P210 CB'S, F21, K4, K5 AND K9 AND PERFORMED GROUND TEST "27 HIGH LIFT SYS PRIMARY SYS TEST-FSEU 2". TEST PASSED.
RT WING OVHT, RTFL. FOUND BLOWN DUCT RT-PACK BAY. DAMAGE TO 4-DUCTS AND SEVERAL STANDOFFS. DUCTS RMV'D. DUCTS AND STANDOFFS ON AOG. DUCTS INSTALLED, RUNS GOOD. PREPPING TO CLOSE PANELS. FOUND RT ENG PNEU MANIFOLD FAILED. DAMAGED 4-DUCTS AND SEVERAL STANDOFFS. DUCTS RMV'D. DUCTS AND STANDOFFS ON AOG. DUCTS INSTALLED, RUNS GOOD. PREPPING TO CLOSE PANELS.
AT SEAT 1F THE EMERGENCY FLOOR LIGHTING IS MISSING. REPLACED MISSING LIGHT, OP CHECKS GOOD.
NR 2 ENG VENT LINE TO THE RESTRICTOR VALVE ON THE DEOILER CRACKED. LINE IS NR 3 BEARING RESTRICTOR VALVE AP39 AIR SUPPLY TUBE. NEW LINE ON AOG. REMOVED NR 3 BEARING RESTRICTOR VALVE AP39 SUPPLY LINE. REMOVED PARTS IN AREA. REPLACED LINE.
CREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: INTERMITTENT O2 LOW INDICATION. EICAS AND STATUS MESSAGE. FOUND 1500 PSI ON BOTTLE, SERVICED BOTTLE TO 1900PSI NO LEAKS NOTED AROUND BOTTLE, SUSPECT INDICATION SEE HISTORY. ACCOMPANIED HAND OVER HAND CHECK OF ACCESSIBLE WIRING BETWEEN CONNECTOR DM35447 & D5677P, NO DEFECTS NOTED. REPLACED TRANSDUCER. OPS NORMAL.
ELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). ADVISORY FOUND RT IDG OVERFILLED. SERVICED CORRECTLY. RECONNECTED IDG. RAN ENGINE. IDG INOP. REPLACED RIGHT IDG. SECURED ALL ELECTRICAL OIL CONNECTIONS AND SAFTIED QUAD RING AND OPS CKED. OP CKS NORMAL.
OXYGEN MASK PROBLEM CREW COMMENTS, MASK WILL NOT DEFLATE MASK STAYS INFLATED. OK TO CONTINUE SECOND OBSERVERS SEAT INOP. DUE TO O2 MASK INOPERATIVE, MISSING. REPLACED O2 MASK, OP'S CK'D NORMAL. OLD UNIT REMOVED AT IAD.
EXT EMERGENCY LIGHT IS OUT. RELAMPED.
SEAT 13F AFT EMERGENCY LIGHT IS MISSING. SUPPLEMENTAL DATA UPDATE, REPLACED LIGHT ASSEMBLY.
SEAT 32C EMERGENCY LIGHT IS OUT. REPLACED LIGHT ASSEMBLY.
LEFT WING FUEL JETTISON VALVE LEAKING AND PANEL REMOVED FROM BOTTOM OF WING, PANEL 543AB. REPLACED VALVE AND ACTUATOR. NEEDS OPS CHECK.
STATUS PAGE FLIGHT CONTROL SYSTEM. REPLACED LEFT FLIGHT CONTROL BATTERY.
CREW REPORTS: FLIGHT ATTENDANT REPORTED ABNORMAL SOUND FROM ENG 1 DURING START, CREW SHUTDOWN ENG, RESTART WITH SAME RESULTS, NO REPORT OF ANY ABNORMAL ENG PARAMETERS OR EICAS MESSAGES, ENGINE WAS RUN AT 50% N1 WITH ALL PARAMETERS NORMAL. ACCOMPLISH CHECKS WITH NO DEFECTS FOUND. T-S AND FOUND APU SURGE VLV BAD. REPLACED VALVE AND DID SEVERAL ENGINE STARTS, ALL NORMAL.
INFLATION CYLINDER OUT OF GREEN BAND. IMPROPER CYLINDER FILL. TOP OFF CYLINDER.
EXTERIOR EMERGENCY LIGHTS ON DOORS 3 AND 4 LT INOP. RELAMPED EMERGENCY LIGHTS ON DOORS 3 AND 4 LEFT, OPS CHECK OK.
AFT EEL LIGHT ON SEAT 3E INOP. RESEATED CONNECTOR, OPS CHECK OK.
STATUS MSG APU BATTERY. REPLACED BATTERY, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SWICH PER MM24-09-00. THIS CLEARED STORED FAULTS. AFTER RELOAD ACCPLISHED TEST OF APU BATTERY & CHAGER TO ENSURE PROPER OPS. NO MESSAGES FOUND ON EICAS. ACCOMPLISHED OPS TEST OF THE APU BATTERY. OPS CHECKS GOOD.
STATUS MSG BATTERY CHARGER APU. REPLACED-CHARGER, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SW PER MM24-09-00 PG201 THIS CLEARED THE FAULTS. AFTER RELOAD ACCOMPLISHED TEST OF APU BATTERY & CHARGER. RAN APU FOR HALF HOUR AND THE APU BAT CHARGER POWER CIRCUIT BREAKER ON THE P320 PANEL POPPED. INSTALLED NEW APU BATTERY CHARGER. OP'S CHECKED GOOD.
THE 1E SIDE WALL EMERGENCY LIGHT FELL OFF. REPLACED LAMP. TESTED GOOD.
LT ELEVATOR OTBD PCA ATTACH FITTING IS CRACKED AT LWR CORD INBD LUG, ON ELEVATOR, BY- 80904. LT ELEVATOR REPLACED WITH SERVICEABLE LEASED UNIT ON OV W-US. RIGGED AND OP CHECKED.
SEAT 1F AFT EMERGENCY LIGHT ASSY MISSING. LIGHT ASSY REPLACED AND TESTED NORMAL.
SEAT 1E AFT EMERGENCY LIGHT MISSING. EMERGENCY LIGHT ASSY REPLACED AND TESTED OK.
APU BATTERY CHARGE MESSAGE DISPLAYED ON EICAS. SUSPECT FAULTY BATTERY CHARGER. REPLACED BATTERY CHARGER PER MM 24-31-06. AC OK FOR SERVICE.
"MANUALLY INITIATED ENGINE START TEST". THIS TEST GIVES FAULT, "BACKUP CONVERTER HAS INTERNAL FAULT". SUSPECT FAULTY CONVERTOR. REPLACED BACK UP GENERATOR CONVERTER PER MM 24-25-09. PASSED TEST PER MM 24-25-00. AC OK FOR SERVICE.
FOUND FLT CONTROL SYS STATUS MESSAGE LATCHED WITH NO CORRELATED MESSAGES. FOUND MESSAGE 31-54102. RPL IOM M004, NO HELP. SUSPECT ARINC 629 COUPLER B31208 IN P212 PANE. *NOTE* TURNED ON ALL HYD SYS PER MT 27-005-R1, NO HELP. *NOTE* MSG CAN BE CLEARED BY DOING RT AIMS M004 RESET, BUT, FLT CONTROL SYS STATUS MESSAGE DOES NOT CLEAR. REPLACED ROBBED ADIRU AND UPDATED SOFTWARE, NO HELP. SWAPPED COUPLER B31208 AND RT AIMS M004 WITH LT AIMS M004, NO HELP. RANG OUT WIRING IN BETWEEN COUPLER AND RT AIMS. ALL OK. MSG STILL ACTIVE WITH NO CORRELATED FAULT. PUT SWAPPED AIMS UNIT BACK TO NORMAL. TRIED NEW FCDC BATTERY, SWAPPED LT AND CENTER PRIMARY FLIGHT COMPUTERS, NEW PSA, PROBLEM SEEMS TO BE ON CENTRAL BUSS BETWEEN PFC AND PSA. ALL TESTS PASSING, NO CORRELATING MAINT MSGS. REMOVED EXTERNAL POWER, DISCONNECTED BOTH MAIN AND APU BATTERY. LET PLANE SIT FOR 20 MINUTES THEN REPOWERED. STATUS MESSAGE GONE. RAN PFC TEST IN MAT AND NO FAULTS NOTED. REPOWERED PLANE AGAIN AND STILL GOOD.
FOUND "FLIGHT CONTROL SYSTEM STATUS MESSAGE" LATCHED WITH NO CORRELATED MESSAGES.
NR 2 LT DOOR EMERGENCY LIGHT INOP. SECURED BULB.
ANTISKID EICAS MSG ON TAXI. SUSPECT BRAKE SYSTEM CONTROL UNIT. REPLACED BRAKE SYSTEM CONTROL UNIT AS PER MM 32 -42-01, PASSED MAT TEST. AC OK FOR SERVICE.
FOUND DOOR 4R AFT EMERGENCY EXIT LIGHT LENS COVER MISSING. REPLACED LENS
RECEIVED A REPORT OF A FIRE IN VICINITY OF RT MAIN GEAR FROM CDG TOWER. ACFT DEPLANED IN TAXIWAY (ALL EIGHT SLIDES). NR 4 MLG (RT GEAR RT FRONT) OUTER WHEEL BEARING FAILED. NR 4 MLG (RT GEAR, RT FRONT) OUTER WHEEL BEARING FAILED. RT GEAR FWD AXLE IS HEAT DAMAGED AND CRACKED ON WHEEL NUT THREAD PORTION. REPLACED AXLE ASSY.
BLEED LOOP 2 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR RIGHT DUCT LEAK OVERHEAT DETECTION SYSTEM (DLODS) CARD. SUSPECT POSSIBLE HIGH RESISTANCE. CONNECTOR DP8402 PINS 45 AND 46 HAVE A RESISTANCE OF 136.9 OHMS. SHOULD BE 128.7 (+-12.9) . RE-TORQUED CONNECTORS TO CARD. MEASURES WITHIN LIMIT. ACFT OK FOR SERVICE.
FLIGHT CANCELLED DUE TO RT ENGINE VIBRATION AND METAL CHIPS FOUND ON DETECTOR. ENGINE REPLACED AT LHR. SHOP TEARDOWN REVEALED ONE STAGE-2 HP TURBINE BLADE FRACTURED AT THE AIRFOIL MID-SPAN. THE FRACTURE WAS THE RESULT OF INTERNAL SULFIDATION RESULTING FROM TURBO TIP CONTAMINATION. THIS WAS THE RESULT OF A REPAIR/ MANUFACTURE PROCESS ERROR THAT HAS SINCE BEEN CORRECTED BY PRATT & WHITNEY. UA IS REPLACING SUSPECT CONTAMINATED BLADES AT SHOP VISIT.
DOOR 4L WILL NOT ARM. REMOVED FOREIGN OBJECT. LT SIDE OF GIRT BAR, OPS CHECKED GOOD. AC OK FOR SERVICE.
PRIMARY SLATS FAIL ON FINAL. 10-16-07 REPLACED FSEU 2 PER MM 27-51-01. ACCOMPLISHED MAT TEST AND TEST PASSED. SLAT PROBLEM STILL CHRONIC. REPLACED SLAT PRIMARY CONTROL VALVE PER 27-81-05. LEAK CHECK OK. PERFORMED SLAT PRIMARY CONTROL VALVE TEST. FOLLOWING REPLACEMENT OF THE CONTROL VALVE, THE MESSAGES ARE CLEARED. AIRCRAFT OK FOR SERVICE.
BATTERY CHARGER APU; STATUS MESSAGE RECEIVED. 10-5-07 REPLACED APU BATTERY CHARGER, BATTERY, AND CARD M24406A4 IN PANEL P310, OP CHECKS OK.
LEFT WING INBD FLAP LEADING EDGE AND LOWER SKIN SUSTAINED DAMAGED. [08-14-07] 1R MLG TIRE RECAP CAME OFF DURING TAKE OFF ROLL. DAMAGE TO PANELS 552CB, 551FB AND BULLNOSE OF LT INBD MID FLAP HAS DAMAGE REQUIRING GLASS LAYUP REPAIRED. WING INBD FLAP LEADING EDGE AND LOWER SKIN SUSTAINED DAMAGED DUE TO TIRE FAILURE. DAMAGE IS LOCATED 78" INBD OF OUTBD EDGE. DAMAGED OCCURED OVER THE FWD SPAR WHERE FASTENERS ARE PULLED AND LOWER SKIN IS CRACKED ACROSS 5 FASTENERS TOTALING 6" IN LENGTH.
FLOOR EMERGENCY LIGHTS BY 11D INOP. [06-26-07] RESET SYSTEM. OPS CHECK OK
EXTERIOR EMERGENCY EXIT LIGHTS ADJACENT TO DOORS 3 LEFT AND 2 RIGHT ARE INOPERATIVE. [SUP 06-06-07] RELAMPED.
EMERGENCY EXIT LIGHTS ON SEATS ROWS 11-15 BOTH AISLES ARE INOPERATIVE. [SUP 06-06-07] REPLACED POWER SUPPLY.
EEL LIGHT AT 34C INOP. REPLACED LIGHT ASSY, OPS CHECK GOOD.
EMERGENCY CEILING LIGHT AT SEAT 13F IS OUT. SUPPLEMENTAL DATA UPDATE RELAMPED, OPS CHECKS GOOD.
CREW REPORTED ELECTRICAL ODOR OR SMELL AROUND DOOR 2R. FOOD/DEBRIS BURNT IN WARMING OVEN. OVENS WERE CLEANED.
ESCAPE SLIDE HAS A PUNCTURE ON LOWER INFLATION CHAMBER. PATCHED PER AIR CRUISERS CMM 25-61-32 WITH THREE INCH CIRCLE--PRESSURE TESTED, NO LEAKS. CAUSE OF PUNCTURE IS UNKNOWN.
EMERGENCY LIGHT AT AISLE SEAT 24G INOPERATIVE. RELAMPED, OPS CK GOOD.
SKIN AT STA 624 BETWEEN STRINGERS 46L AND 47L, UNDER LOWER FUSELAGE ANTENNA BASE HAS 2 EA OVERSIZED AND ELONGATED HOLES. MAJOR REPAIR. REPAIRED BELLY SKIN AND INSTALLED NEW INNER DOUBLER.
LT EXTERNAL FUSELAGE SKIN AT STATION 835, BETWEEN STR 25L AND 26L DENTED AND CRACKED. MAJOR REPAIR ACCOMPLISHED. FLUSH REPAIR.
LT & RT AILERON INBD AND OUTBOARD PCU FITTINGS CRACKED. LT AND RIGHT AILERONS WERE REPLACED.
ENGINE FUEL FILTERS ON LT & RT DIFFERENTIAL PRESSURE ACROSS LT FUEL FILTER APPROACHES BYPASS CONDITION. STATUS ENGINE FUEL FILTER DISPLAYED AFTER TAKE-OFF. REMAINED ON FOR APPROXIMATELY 30 SECONDS. FUEL CONTAMINATION CHECKS WERE MADE AT FUELING STATION, NO CONTAMINATION. BOTH FUEL FILTERS WERE REPLACED, SOME DEBRIS FOUND, BUT BELIEVED INSUFFICIENT TO CAUSE BYPASS. ONE FILTER WAS FLOW CHECKED. MAX DELTA-P ACROSS THE FILTER WAS 3 PSID; INSUFFICIENT TO TRIP THE DELTA-P SWITCH. BOTH DELTA-P SWITCHES WERE CHECKED. CLOSED AND OPENED WITHIN SPEC. SWITCHES WERE DISASSEMBLED - NO ANAMOLIES FOUND.
1ST OFFICER'S FWD OUTER WINDSHIELD FAILED. PRESSURIZATION MAINTAINED AT ALL TIMES. THE OUTER LAYER OF GLASS SHATTERED DUE TO ARCING AT THE UPPER BUS BAR FOR THE WINDOW HEAT SYSTEM. THE CAUSE OF THE ARCING WAS DUE TO MOISTURE INGRESS INTO THE ELECTRICAL HEAT SYSTEM BUS BAR AT THE AREA WHERE THE HEAT FILM ATTACHES TO THE BUS BAR. CONTRIBUTING FACTORS OF POOR ADHESION OF THE MOISTURE SEAL AND DELAMINATION IN AND AROUND THE UPPER BUS BAR AREA ALLOWED THE WATER TO PENETRATE INTO THE AREA. REMOVED AND REPLACED THE WINDOW ASSY PER AMM 56-11-01-401.
HAIL DAMAGE DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.
NR 8 SPOILER WILL NOT TAKE LUBRICATION AT CNT OUTBOARD HINGE. MAJOR REPAIR. FITTING REWORKED PER EVA G95-7722. SPOILER REMOVED AND REINSTALLED.
CREW REPORTS LOUD NOISE AND VIBRATION ON RIGHT SIDE OF AIRCRAFT BY ROW 15. *S/D* DUCTS IN AFT OF FORWARD CARGO COMPARTMENT (MIX MANIFOLD AREA) WERE CHECKED, BUT NO DISCREPANCIES WERE FOUND. AIR ON TEST WAS PERFORMED ON RIGHT HAND PACK, AND THERE WAS NO EICAS MESSAGE INDICTING THE RIGHT PACK. AIRCRAFT WENT BACK TO REVENUE SERVICE WITH NO FURTHER INCIDENT.
POOR AIR QUALITY IN THE AIRCRAFT. *S/D* PROBLEM COULD NOT BE DUPLICATED ON GROUND. HOWEVER, WHEN CHECKING LT CONDENSER/REHEATER, IT WAS FOUND CLOGGED. A CLOGGED CONDENSER/REHEATER CAN CAUSE PACK LOW FLOW PROBLEM WHICH MAY CONTRIBUTE TO POOR AIR QUALITY. THE LT CONDENSER/REHEATER WAS REPLACED. AIRCRAFT WENT BACK TO REVENUE SERVICE WITHOUT FURTHER POOR AIR QUALITY PROBLEM.
MAJOR REPAIR REPORTING: DURING ROUTINE MAINTENANCE A CRACK WAS FOUND IN ONE OF THE MID CHORD ANGLES (P/N:141W8519-1) ON THE MAIN DECK FLOORBEAM AT STATION 246, LBL 38.5. ACCOMPLISHED REPAIR PER BOEING STRUCTURAL REPAIR MANUAL 53-10-51, FIGURE 201, REPAIR TYPE 1.
LEFT PACK COMPARTMENT DOOR DEPARTED AIRCRAFT IN FLIGHT. AIRCRAFT RETURNED TO IAD. *S/D* LEFTHAND PACK DOOR WAS FOUND MISSING. IT APPEARED THAT AS PORTIONS OF THE DOOR BROKE LOOSE, THEY HIT THE PARTS INSIDE LEFTHAND PACK BAY LEAVING PUNCTURES AND DENTS ON SEVERAL COMPONENTS (CONDENSER/REHEATER, FAN AIR DIFFUSER HOUSING, AND OTHER DUCTING). PARTS REPLACED INCLUDE: ALL DAMAGED PARTS IN LT PACK BAY, LT PACK BAY DOOR (P/N 149W2300-1), AND FITTINGS (P/N 145W2401-3 & 145W2403-3). INCIDENT IS UNDER INVESTIGATION.
EN ROUTE EWR - DEN, CREW OXYGEN LOW EICAS MESSAGE DISPLAYED WITH STATUS PAGE INDICATING 500 PSI. DIVERTED TO IND. *S/D* FOUND CREW OXYGEN BLEED VALVE LEAKING (P/N: B19820-1). BLEED VALVE WAS REPLACED.
EN ROUTE CDG-IAD, LOST RIGHT HIGH FREQUENCY RADIO. DIVERTED TO LHR. *S/D* FAULT, INTERNAL TO THE HIGH FREQUENCY ANTENNA COUPLER (P/N: 792-6140-001) CAUSED THE COUPLER TO RECEIVE BUT NOT TRANSMIT. UNIT WAS REPLACED AND FULL SYSTEM FUNCTIONALITY WAS RESTORED. TESTING VERIFIED REPORT OF RECEIVE BUT NOT TRANSMIT FUNCTION AND ADDITIONAL UNIT ANALYSIS IS SCHEDULED.
PACK MODE L LEFT PACK AIR CYCLE MACHINE HAD FAILED MESSAGE RECEIVED AND FLIGHT CREW NOTICED SMOKE IN COCKPIT AT TOP OF DESCENT. *S/D* PACK MODEL MESSAGE WAS DUE TO AIR CYCLE MACHINE (P/N 810209-3) SEIZING. HAMILTON STANDARD AND BOEING ARE WORKING TO IMPROVE THE ACM RELIABILITY. ACM TEARDOWN SHOWED THAT ACM FAILURE WAS NOT RELATED TO THE SMOKE INCIDENT.
APU GENERATOR DROPPED OFF LINE AT DEPARTURE. FOUND GENERATOR FEEDER CABLE DAMAGED FROM TERMINAL LUG. *S/D* THE CAUSE OF THE APU GENERATOR DROPPING OFF LINE WAS DAMAGE TO THE PHASE C WIRE (W7860-0003-3/0). THE WIRE WAS REPLACED AND THE APU GENERATOR SYSTEM OPERATIONAL CHECKED. THE CAUSE OF THE OVERHEAT ON THE TERMINAL COULD NOT BE PRECISELY DETERMINED. CAUSES COULD INCLUDE TERMINATION METHOD FOR THE WIRE ASSEMBLY OR METHOD OF HARDWARE INSTALLATION AT THE TERMINAL.
APU WILL NOT START IN EITHER ELECTRICAL OR PNEUMATIC START MODE. *S/D* REMOVED AND REPLACED APU BATTERY CHARGER. PROBLEM PERSISTED. FOUND APU STARTER DAMAGED. REPLACED ELECTRIC STARTER (P/N 2704442-4) AND CLUTCH ASSEMBLY. OPERATIONALLY CHECKED NORMAL. SUSPECT CAUSE RELATED TO BOEING SERVICE RELATED PROBLEM (SRP) 777-SRP-49-0028 AND SERVICE BULLETIN 777-24-0024.
DURING FLAT FIRING OF SLIDE RAFT (P/N 62772-202) (S/N 0021) IN CONJUNCTION WITH SHOP OVERHAUL VISIT, A ONE INCH TEAR DEVELOPED IN THE LOWER TUBE UNDER THE GIRT. UNIT SENT TO VENDOR FOR REPAIR AND EVALUATION. *S/D* AFTER REVIEW BY VENDOR, CAUSE OF FAILURE COULD NOT BE PRECISELY DETERMINED.
RIGHT INBOARD NR 8 LEADING EDGE SLAT CENTER PAIR OUTBOARD ARM (114W2804-8) CRACKED AT UPPER FLANGE NEAR AFT END ROLLERS. REPLACED ARM (114W2804-8).
WITH A/P ENGAGED AND SPEED BRAKE EXTENDED TO FULL UP POS. ON DESCENT PLANE TRIED TO NOSE DIVE UP TO 10 DEG NOSE DOWN. DESCENT RATE WENT TO 5880 FPM. DISENGAGED A/P WORKED FINE. TRIED A 2ND TIME WITH A/P ENGAGED SAME PROBLEM. WITH A/P DISENGAGED USED SPEED BRAKE TWICE WITH NO NOSE DOWN EXCESS.
CENTER HYDRAULIC SYSTEM FLUID PRESSURE LOSS AFTER TAKEOFF. AIRCRAFT CONTINUED TO IAD, LANDED UNDER AMBER ALERT. *S/D* CAUSE ATTRIBUTED TO LEAK AT THE LEFTHAND MAIN LANDING GEAR ACTUATOR PRESSURE HOSE CAUSED BY CHAFING AGAINST HOSE GUIDE. INSTALLED NEW HOSE WITH A CHAFE GUARD FOR ADDITIONAL PROTECTION. FLEET WIDE CHECK ACCOMPLISHED.
SPOILERS ADVISORY MESSAGE FAILURE OF ONE OR MORE SPOILER PAIRS. *S/D* FOUND CONNECTOR D2129J BURNED AND REPLACED CONNECTOR D2129J.
BACKUP ELECTRICAL SYSTEM EICAS MESSAGE DISPLAYED, INDICATING FAILURE OF BACKUP ELECTRICAL SYSTEM. BACKUP CONVERTER AND LEFTHAND BACKUP GENERATOR WERE REPLACED. VENDOR CONFIRMED FAILURE OF THE PMG STATOR WINDINGS IN THE BACKUP GENERATOR. ALSO, THE BACKUP CONVERTER WAS FOUND TO BE DEFECTIVE.