| JETBLUE AIRWAYS CORPORATION (YENA) | Operator | 2025-07-13 – 2025-07-13 | Operator named in NTSB report |
| JETBLUE AIRWAYS CORP | Operator | 2025-07-13 – 2025-07-13 | Operator named in NTSB report |
Accident & incident history
Maintenance disclosures
FLT # 1371 LGA-FLL." SOCKS SMELL DURING FINAL APPROACH INTO FLL .; PER INFO NOTICE 2017-T015M, CHECKED TRAX FOR 30 DAY HISTORY, NONE FOUND, INSP. APU FOR LEAKS AND OIL LEVEL, ALL IN LIMITS AND GOOD, AND VERIFIED ENG OIL LEVELS AT CORRECT LEVELS. FAULT HAS BEEN ISOLATED TO TYPE 10, MISCELLANEOUS, PER TSM 05-50-00-810-085-B/TSM 05-50-00-810-085-D. A/C OK FOR SERVICE."
FLT#1791, LGA-PBI. "ODOR EVENT ABOUT 15000 APU NOT ON VMC CONDITION; COMPLIED WITH INFORMATION NOTICE 2017-T015M, STEPS 1&2. IDENTIFIED ODOR TYPE 9 PER TSM 05-50-00-810-085-B. DECONTAMINATION A WAS ACCOMPLISHED 21-00-00-615-802. (HEPA FILTERS REPLACED). AIRCRAFT IS OK FOR SERVICE."
FLT#2922, NAS-JFK. (AIRCRAFT PERFORMED AIR TURNBACK TO NAS) "ENGINE #2 BANG AND SEIZE. INSPECTED ENGINE #2 IAW AMM 05-51-26 FOUND NO AIRFRAME DEFECTS ENGINE #2 METAL, DEBRIS FOUND IN EXHAUST REMOVED AND REPLACED #2 ENGINE IAW AMM 71-00-20-400-040. REFERENCE WO #1426688.
FLT#2534, PBI-DCA. 'FWD ENTRY DOOR EMERGENCY LIGHTS INOP; REMOVED AND REPLACED FWD EPSU (10WL) REF AMM 33-51-38,OPS CHECK GOOD.'
FLT#1251, HPN-PBI. (AIRCRAFT DIVERTED TO JFK) .' FLAPS LOCKED FLAPS INOP; REF LP 4041509-1 (REF AWN 27-51-14 AND ASM 27-51-07 CHECK WIRING FOUND WIRE # 2751-4528 DAMAGE BETWEEN 34 CV R WING TIP BROKE AND 4008 VS ACCOMPLISHED A GRADE 1A REPAIR IAW ESPM 20-53-21 OPS TEST OF THE WING TIP BRAKE IAW AMM 27-51-00 EXTENSION AND RETRACTION OF THE FLAPS IAW 27-50-00 ALL OPS CHK OKAY AC OKAY FOR SVC) AND LP 4041508-2 (PERFORMED TS PER TSM 27-51-00-810-837- A DURING CONTINUITY CHECK FOUND OPEN BETWEEN SFCC-2 PIN 14K AND 34 CVB PIN A SOLENOID CONNECTOR CONFIRMED CONTINUITY BETWEEN SFCC 2 PIN 14K AND 94 VC PIN 2 FUTHER TS REQUIRED) FOR CORRECTIVE ACTIONS.
FLT#363,BOS-UVF. ' LEVEL 1 TRANSIENT ODOR REPORTED BY AFT FA'S DURING DESCENT; COMPLIED WITH INFO NOTICE 2017 - T015 SECTION A ISOLATION FAULT TYPE 101 (A) 1X PCD TSM 05 -50 -00 -810 -085B -055D. A/C OK FOR SERVICE.'
FLT#1570, LAX-CUN. 'INBOUND INFLT CREW REPORTED THAT ON SHORT FINAL FOR FLIGHT 1570 A STRONG CHEMICAL ODOR WAS IN THE GALLEY. IT CAUSED MED BURNING SENSATION TO THEIR NOSE AND THROAT. SUBSIDED IN 10 MINS; COMPLIED WITH INFORMATION NOTICE 2017-T015J SECTION A ISOLATED FAULT.A/C IS OK FOR SVC.MCC BOB NOTIFIED.'
FLT#361, JFK-BGI. (AIRCRAFT PERFORMED AN AIR TURN BACK TO JFK) 'AIR ENG 2 BLEED FAULT; REMOVED AND REPLACED THERMOSTAT (7170HM2) ON ENG #2 IAW AMM 36-11-43. OPS CHECK GOOD. AIR ENG 2 BLEED FAULT MSG NOT DISPLAY ON ECAM.'
FLT 1942, LGA-DEN. AIRCRAFT DECLARED AN EMERGENCY. AFTER LOWERING LANDING GEAR. BRAKES ALTN LT BRAKE RELEASED, RESET ALTERNATE BRAKES AND PERFORMED BITE TEST IAW AMM 32-43-00-710-002-A. NO FAULTS NOTED.
FLT #1505, EWR-FLL. (EMERGENCY DECLARED)PUT LG DOWN FOR LANDING RECEIVED ECAM "LG DOORS NOT CLOSED" FOR RIGHT NOSE GEAR DOOR ; AFTER SECOND APPROACH RECEIVED "L/G SYSTEM DISAGREE UPON LANDING. INSP NLG AREA AND FOUND NLG PROX SNSR 19GA TARGET ASSY MISSING. INSTALLED NEW TARGET ASSY IAW 32-31-73-400-005A. PERFORMED LGCIU 1 & 2 BITE CHK IAW AMM 32-69-00-740-001A. OPS CHK GOOD
FLT # 38, SJO-FLL. OVERHEAD EMERGENCY ISLE LIGHT ABOVE ROW 18 INOP ; FOUND GROUND WIRE LOOSE - SECURED + OPS CHECK GOOD REF 35-50-00 A/C OK FOR SVC
DURING HEAVY MAINTENANCE, FAULT EPSU 10WL; (REF AEROMAN NR 2021 62778 WO 2021 73/1) R & R EPSU BATTERY 10WL IAW AMM 33-51-38 OPS CHECKS OK IAW AMM 33-51-0-710-001-A
DURING HEAVY MAINTENANCE, FAULT EPSU 12WL; (REF AEROMAN NR 2021-62693 WO 2021 73/1) R &R BATTERY EPSU 12WL IAW AMM 33-51-38 OPS CHECKS OK IAW AMM 33-51-00-710-001-A
DURING HEAVY MAINTENANCE, CRACK INDICATION FR43 LH SIDE MIDDLE HOLE OF SIDE BOX BEAM; (REF AEROMAN 2021-73/1/2021-62553) ACCOMPLISHED EC A320-53-1251 FR43 LH SIDE MIDDLE HOLE OF SIDE BOX BEAM
DURING HEAVY MAINTENANCE, CRACK INDICATION FR43 RH SIDE AFT FASTENER OF SIDE BOX BEAM; (REF AEROMAN NR 2021-73/1-2021-62557) ACCOMPLISHED EC A320-53-1251 FR43 RH SIDE AFT HOLE OF SIDE BOX BEAM
DURING HEAVY MAINTENANCE, CORROSION LOWER SILL ON FR68 AT LEVEL STR 23R AT AFT GALLEY AREA RELATED CPCP 534143-01; PERFORMED PERMANENT REPAIR ON LOWER SILL ON FR68 AT LEVEL STR 23R AT AFT GALLEY IAW A320 SRM 53-41-14-300-001 REPAIR PRICCIPLE 5 TOOL USED DIGITAL CALIPER PN 500-197-30 SN A18234378 AND DUE DATE JUL 30 -21 ALL WORK ACCOMPOLISHED ON AEROMAN NR 2021-62689
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM +Y1292 BTW FRAME 16 AND FRAME 20 AT FWD GALLEY AREA CPC RELATED 531189-01; REMOVED AND REPLACED FLOOR BEAM +Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA IAW A320 SRM 51-42-11 AND DWG D53110984, D53110920, AND EA 53-0055-21 PART #1 AND EC A21-159-01 TOOL USED CALIPER PN 500-197-30 SN A18234378 DUE DATE JUL-30-21 COMPLETED MX-220
DURING HEAVY MAINTENANCE, CORROSION TRAILING EDGE TOP SKIN LOWER SURFACE OVERHANG BETWEEN RIB7 TO RIB 8 RELATED CPCP MPD TASK 572178-1 ON RH WING REF AEROMAN NR 2021-62518; PERFORMED PERMANENT REPAIR ON EXACTLY LOCATION BTW WX3622 OUTER JACK RIB AND RIB7A WX4013 TRAILING EDGE TOP SKIN LOWER SURFCE ON RH WING IAW EA 57-0044-21 PART #1 PART#2 AND EC A21-165-01. THIS REPAIR IS CLASSIFIED CATAGORY A AND NO FURTHER INSPECTION IS REQUIRED. TOOL USED CALIPER PN 500-197-30 SN A18234378 DUE DATE JUL 20-21 NDT EQUIPMENT PN NORTEC600D SN 60009161631 DUE DATE DEC 01-21 THICKNEWSS GUAGE PN 45MG SN 1300633701 DUE DATE APR 13-21 COMPLETED MX 220 FORM BY CPCP PROGRAM. ALL WORK PERFOMED ON AEROMAN NR 2021-62518
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y1292 BTW FRAME 16 AND FRAME 20 AT FWD GALLEY AREA CPCP RELATED 531189-01; REMOVED AND REPLACED FLOOR BEAM -Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA IAW A320 SRM 51-72-11 DWG D53110920 AND D53110984, TOOL USED CALIPER PN 500-752-20 SN B1610263 DUE DATE AUG 06-21 COMPLETED MX-220 FORM BY CPCP PROGRAM. ALL WORK ACCOMPLISHED ON AEROMAN NR 2021-62675
DURING HEAVY MAINTENANCE, AFT CABIN FLOOR LH SIDE FR 69-70 Y1292FLOOR SUPPORT WEB CORRODED; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00015 ) UPON EVALUATION OF SHEAR PLATE AT FR 69-70 Y1292 FOUND SHEAR PLATE TO BE CRACKED. REMOVED AND REPLACED SHEAR PLATE IAW A320 SRM 51-42-11
DURING HEAVY MAINTENANCE, AFT CABIN FLOOR RH SIDE FR 69-70 -Y1292 FLOOR SUPPORT WEB CORRODED; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00014) UPON EVALUATION OF SHEAR PLATE AT FR 69-70 -Y1292 FOUND SHEAR PLATE CRACKED. REMOVED AND REPLACED SHEAR PLATE IAW A320 SRM 51-42-11
DURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM Y1292 AT FR 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00013 ) EVALUATED CORROSION ON FLOOR BEAM Y 1292 AT FR 68 MATERIAL LOSS OF .026 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11 AND 53-00-14
DURING HEAVY MAINTENANCE, AFT WET AREA FR68 -Y300 FLOOR BEAM SMALL SPOT OF CORROSION; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00016 ) EVALUATED CORROSION AT FLOOR BEAM -Y300 FR 68 MATERIAL LOSS OF .029 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11 AND 53-00-14
DURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM -Y1292 AT FR68. EVALUATED CORROSION ON FLOOR BEAM -Y1292 AT FR 68, MATERIAL LOSS OF .035 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11 AND 53-00-14
DURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM -Y765 AT FRAME 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00011 ) EVALUATED AREA FLOOR BEAM -Y765 AT FR 68 CORROSION MATERIAL LOSS OF .037 IS OUT OF LIMITS REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11 AND 53-00-14
DURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM Y765 AT FR 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00012 ) REMOVED AND REPLACED FLOOR BEAM AFT WET AREA Y765 AT FR 68 IAW A320 SRM 51-42-11 MATERIAL LOSS OF .022 IS OUT OF LIMITS IAW A320 SRM 53-00-14
FLT 739, EMERGENCY DECLARED. LOUD NOISE AND VIBRATION UNDER OUR FEET ON BOTH SIDES WHEN SMOKE AND FUMES INITIATED BLOWER MOTOT, SWITCHED OFF, VIBRATION STOPPED AND FUMES DISSIPATED AFTER A FEW MINUTES . AT TOP OF DESCENT FUMES CAME BACK OXYGEN MASKS DONNED AGAIN.
FLT 2894, MBJ-BOS. CIDS 1 FAULT ON 11WL EMERGENCY LIGHT BATTERY; REMOVED & REPLACED EMERGENCY BATTERY & POWER SUPPLY IAW AMM 33-51-38. OPS CHECKS GOOD.
FLT 2894, MBJ-BOS. CIDS 1 FAULT ON 11WL EMERGENCY LIGHT BATTERY; REMOVED & REPLACED EMERGENCY BATTERY & POWER SUPPLY IAW AMM 33-51-38. OPS CHECKS GOOD.
FT # 391, BOS-TPA. EMERG LIGHT TEST BATTERY FAULT AT 13WL; REMOVED & REPLACED EMERGENCY LIGHT BATTERY AT 13WL PER AMM 33-51-38.
FLT 391, BOS-TPA. EMERG LIGHT TEST BATTERY FAULT AT 10WL; REMOVED & REPLACED EMERGENCY LIGHT BATTERY AT 10 WL PER AMM 33-51-38.
FLT 894, STI-EWR. PASSING THRU 14,000 ON DECENT, CAPT SMELLED DIRTY SOCK ODOR ALSO NOTICED HP VALVES WERE OPEN, ON BLEED PAGE. ISOLATED NR 1 PACK AND SMELL WENT AWAY CABIN ATTENDANTS DID NOT SMELL ANYTHING. COMPLIED WITH INFO NOTICE 2017-T015C SECTION A. A/C OK FOR SERVICE RUN ENG NR 1 AND PACK 1 FOR 10MINS. COULD NOT DUPLICATE ODOR.
FLT 1097, BOS-PHL. DURING CRUISE FLIGHT AT FL 380, AFT CARGO SMOKE DET OCCURRED. DECLARED AN EMERGENCY. DIVERTED TO PHL. PERFORMED ECAS ACTIONS - DISCHARGED AFT CARGO AGENT 1. GOT ANOTHER RED SMOKE DET ECAM, THEN AFT CRG BTL 1 FAULT AND AFT VRG DET FAULT ECAM. AS PRECAUTION, DISCHARGED BTL 2 ECAM 1 CONTINUED! ALL QRH + ECAM COMPLIED WITH. LANDED UNDERWEIGHT AT 1300,000LBS. FIRE/RESCUE PERFORMED IR CHECK OF AFT CARGO COMPARTMENT- CHECKED OK. THEN THEY PERFORMED A VISUAL INSPECTION OF FWD + AFT CARGO COMPARTMENTS, CHECKED OK; INSPECTED BOTH FWD AND AFT CARGO COMPARTMENTS. NO EVIDENCE OF SMOKE OR FIRE. BOTH COMPARTMENTS ARE CLEAN . R & R CARGO FIRE BOTTLE PER AMM 26-23-42: TESTS OK AT THIS TIME. ITEM CLEARED, MX-4 UPDATED, PLACARD REMOVED, MCC NOTIFIED. R & R CARGO FIRE BOTTLE PER AMM 26-23-42: TESTS OK AT THIS TIME. ITEM CLEARED, MX-4 UPDATED, PLACARD REMOVED, MCC NOTIFIED. PER PFR SMOKE DETECTOR 3WH FAULT. REPLACED 3WH CARGO SMOKE DETECTOR PER MM 26-16-15 CHK OK. CLEARED MEL MDDR.
EPSU (12WL) FAILED CAPACITY CHECK IAW T/C 33-51-00-710-003. R & R THE EPSU IAW AMM 33-51-38. OPS CHECKED GOOD.
DISCOVERED 23F CABIN SIDEWALL LIGHT BURNED OUT. THERE WAS AN ASSOCIATED BURNED ELECTRICAL ODOR IN GALLEY; REPLACED THE LAMP. OPS CHECK PASSED. ACCOMPLISHED TSM 24-00-00-810-823. NO OTHER ELECTRICAL ODORS NOTED IN CABIN OR GALLEY AREA. NO BREAKERS TRIPPED. INSPECTION OF WIRING IN AREA OF 23F SIDEWALL FOUND TO BE OK IAW AMM 33-21-11.
DURING ROUTINE MAINTENANCE, OVERHEAD EMERGENCY LIGHT AT ROW 18 WAS FOUND TO BE INOPERATIVE. FOUND THAT CONNECTOR HAD BACKED OFF FROM CONNECTION POINT. RECONNECTED WIRES AND PERFORMED OPS CHECK. OPS CHECK PASSED.