Accident & incident history
Maintenance disclosures
SMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW.SMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM TASK 05-51-58-800-801-C3 DUE TO AN INCIDENT REPORTED BY THE CREW. C/W AMM 05-51-58-800-801-C3, CONDITIONAL INSPECTION AFTER SMOKE/ODOR, FOUND 5 OVENS IN AFT GALLEY VERY DIRTY AND DEFERRED THE OVENS. FORM 46.6020 SUBMITTED TO TOMC.
RIGHT ENGINE COMPRESSOR STALL ON APPROACH. IAW AMM 72-00-00, REV 106. ON ARRIVAL FOUND NR 2 ENGINE WITH THE LOW PRESSURE COMPRESSOR EXIT FAIRING COMPLETELY DETACHED AND STUCK ON THE BYPASS GUIDE VAINS. IAW AMM 72-00-00 REV106 ALL FAN BLADES TRAILING EDGE SIDE FOUND DAMAGED BY THE FOB. IAW AMM 72-00-00, REV 106 AFTER INSPECTION FOUND PARTICLES OF THE FOD INGESTED IN THE ENGINE CORE. IAW AMM 78-31-00 REV 106 FOUND ON LT THRUST REVERSE DAMAGE FROM FOD AT 8 O`CLOCK DIMENSIONS 20MM X 14MM & 9 O`CLOCK DIMENSIONS 10MM X 10MM.
RIGHT ENG FAILED. OIL PRESSURE ZERO. LOUD BANG & SURGE. DEBRIEFED CREW, ENG WINDMILLED FOR 2.5HRS, SHUTDOWN AFTER A COMPRESSOR STALL AS PRECAUTION DUE TO FLUCTUATING OIL PRESS. BUG SHOWS SERVICE REQUIRED. ENG OIL QTY REMAINED AT 23QTS. LOWER ENG HAD EVIDENCE OF OIL LEAK. ENG SHUTDOWN AFTER OIL PRESSURE DROPPED TO ZERO FOLLOWED BY COMPRESSOR STALL, ENG SHUTDOWN WAS MANDATORY PER CHECKLISTS. PER FIM TASK 71-05 TASK 819, FOUND A LARGE AMOUNT OF METAL CHIPS & FLAKES ON MAIN GEARBOX CHIP DETECTOR AT FWD FACE OF GEARBOX & MASTER CHIP DETECTOR ON OIL TANK, MAIN GEARBOX CHIP DETECTOR LEAKS OIL & DOES NOT STOP WHEN CHIP DETECTOR REMOVED, SUSPECT METAL DEBRIS HOLDING IT OPEN. ALL OTHER CHIP DETECTORS SHOW NO CONTAMINATION, BUT OIL IS DARK. BOTTOM PART OF ENG WET WITH OIL. FOUND NO DEBRIS OR OIL OR LIQUID IN ENG INLET OR EXHAUST. REMOVED #2 ENG GEARBOX CRANK PAD COVER TO MANULLY TURN N2 ROTOR. FOUND GEARBOX CRANK PAD HEX DRIVE SEIZED, UNABLE TO TURN GEARBOX & N2 ROTOR.
3R COVER FOR ARMING LEVER DOESNOT LIE FLUSH. REPLACED R3 DOOR SLIDE SWTICH LEVER COVER HINGE REF IPC 52-11-25-13A ITEM 635, OPS CHECK GOOD.
RIGHT ENGINE, EGT LIMIT EXCEEDED, MAINT MSG 77-62122, VISUAL CHECKED RIGHT ENGINE EXHAUST LAST STAGE TURBINE BLADE BROKEN.
FA BUNK EMERGENCY LIGHT IS COMING ON FOR 2 SEC THEN OFF CONTINUO USLY EMERGENCY LIGHTS IN THE CABIN CREW REST FOUND TO OPERATE NORMALLY ON ARRIVAL. OPERATIONAL TEST CARRIED OUT IAW AMM 33-51-15 AND FOUND SERVICEABLE
EA5310-07557 REV A OP003 (AD2019-11-02) 1EA FASTENER HOLE CRACK FOUND ON BS1035 LH RING CHORD TRANSFER REF. NON-ROUTINE WO.3966370. WING CENTER TANK LH BS1035 AT LBL81.30 FRONT SPAR CHORD REPAIRED AS PER EC/RA5710-02905 REV - PART 1 INTERIM REPAIR INSTRUCTION ITEM 1,INSP REQUIREMENT REFER EC/RA5710-02905 REV.PART 1,ITEM 2 AND ITEM3.
REFERENCE 9925954 EA5310-07557 REV A OP007 AD2019-11-02 STEP 22 1EA HOLE FND CRACK ON CTR TANK RING CHORD LAYER DETAIL REF TO ATT REPORT TRANSFER REF NON - ROUTINE WO.3969930 WING CENTER TANK RH FRONT SPAR RING CHORD AT RBL 81.30 REPAIRED AS PER EC/RA5710-02899 REV - PART 1 INTERIM REPAIR INSTRUCTION ITEM 1,INSP REQUIRMENT REFER EC/RA5710-02899 REV.PART 1,ITEM 2 AND ITEM3. WING CENTER TANK RH FRONT SPAR RING CHORD AT RBL 81.30 REPAIRED AS PER EC/RA5710-02899 REV - PART 1 INTERIM REPAIR INSTRUCTION ITEM 1,INSP REQUIRMENT REFER EC/RA5710-02899 REV.PART 1,ITEM 2 AND ITEM3.
REFERENCE 9925919 EA5310-07557 REV A OP007 AD2019-11-02 STEP 22 2EA HOLES FND CRACK ON CTR TANK FRONT SPAR LWR CHORD LAYER DETAIL REF TO ATT REPORT TRANSFER REF NON - ROUTINE WO.3969918 WING CENTER TANK RH FRONT SPAR LOWER CHORD AT RBL 81.30 REPAIRED AS PER EC/RA5710-02899 REV - PART 1 INTERIM REPAIR INSTRUCTION ITEM 1,INSP REQUIRMENT REFER EC/RA5710-02899 REV.PART 1,ITEM 2 AND ITEM3. WING CENTER TANK RH FRONT SPAR LOWER CHORD AT RBL 81.30 REPAIRED AS PER EC/RA5710-02899 REV - PART 1 INTERIM REPAIR INSTRUCTION ITEM 1,INSP REQUIRMENT REFER EC/RA5710-02899 REV.PART 1,ITEM 2 AND ITEM3.
DR L4 EMER LT BATT PACK CHARGER M33407 TEST FAIL. DR L4 EMER LT BATT CHARGER M33407 REPLACED AND TESTED NORMAL IAW AMM33-51-06
DR L3 EMER LT BATT PACK CHARGER M33405 FAIL. DR L3 EMER LT BATT CHARGER M33405 REPLACED AND TESTED NORMAL IAW AMM33-51-06.
DR L1 EMER LT BATT PACK M33424 TEST FAIL TRANSFER REF NON - ROUTINE WO.3883073 AND DR L1 EMER LT BATT M33424 REPLACED AND TESTED NORMAL IAW AMM33-51-06.
EA5310-07557 REV A OP007 AD2019-11-02 STEP28 RH STA1035 FX SKIN AT LONGERON FTG AREA FND 1EA CRACK AS MARK AND THE CRACK WITHIN THE TRIM BOUNDARY DETAIL REF TO ATT REPORT TRANSFER REF NON - ROUTINE WO.3969937 AND ORIG BY V924733 FX BS993-1035 BTW S35R-37R SKIN REPAIRED WITH A REPAIR FILLER AND REPAIR DOUBLER INSTALLED IAW EA5310-07557 REV A OP20.
EA5310-07557 REV A OP003 AD2019-11-02 2EA CRACK FND AT SKIN AND FASTENER HOLE ON BS1035 LH UNDERWING LONGERON FX TRANSFER REF NON - ROUTINE WO.3966647 AND ORIG BY V914372 FX BS993-1035 BTW S35L-37L SKIN REPAIRED WITH A REPAIR FILLER AND REPAIR DOUBLER INSTALLED IAW EA5310-07557 REV A OP14.
EA5510-01896 REV C OP005 AD2013-08-02 1EA CRACK FOUND ON LH ELEV O/B ACTUATOR FITTING PLS PRINT AND ACCOMPLISH OP09 OF THIS EA TO REMOVE AND REPLACE THE CRACKED ACTUATOR FITTING TRANSFER REF NON - ROUTINE WO.3919768 AND ORIG BY V925919 LH ELEV O/B ACTUATOR FITTING REPLACED IAW EA5510-01896 REV C OP9.
DURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33098 REF HAECO NON-ROUTINE NO.9452854 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33098 AND TEST OK AS PER AMM 33-51-06-960-802 REV 97.
DURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33408 REF HAECO NON-ROUTINE NO.9452854 -ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33408 AND TEST OK AS PER AMM 33-51-06-960-802 REV 97.
DURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33405 REF HAECO NON-ROUTINE NO.9452854 -ORIGINATED BY EMP V905467 SEPC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33405 AND TEST OK AS PER AMM 33-51-06-960-802 REV 97.
DURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACITY ON M33097 REF HAECO NON-ROUTINE NO.9452854 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33097 AND TEST OK AS PER AMM 33-51-06-960-802 REV 97.
DURING EMERGENCY LIGHT OPERATIONAL CHECK FOUND R/H DOOR NO.2 SLIDE OVERWING LIGHT INOP REF HAECO NON-ROUTINE NO.9452361 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7031. PERFORMED BY EMP V903219,IDT BY EMP V905467. REPLACED THE R/H DOOR 2 SLIDE/OVERWING LIGHT LAMP AND TEST OK AS PER AMM 33-51-04 -960-801 REV 97.
WATER NOT DRAINING IN AFT OF AIRCRAFT. LAV SINKS, GALLEY DRAINS BACKING UP. REPEAT. UNCLOGGED AFT DRAIN MAST, VERIFIED AFT GALLEYS AND AFT LAV SINKS ARE WORKING NORMAL, PERFORMED DRAIN MAST HEATER OPERATIONAL CHECK AS PER AMM 30-71-00 VERIFIED OPS CHECKS SATISFACTORY.
FUSELAGE SKIN STA 1035 S37L-38L FND EXISTING CHAFING. FUSELAGE SKIN STA 1035 STR 37L-38L CHAFING AREA REPAIRED AS PER ECRA 5343-01046 REV.
FOUND 1 EA HOLE CRACK AT 6:00 OâCLOCK AFTER OPEN HOLE HFEC INSP REF SB 777-53A0081 FIGURE 10 CIRCLE NOTE 2. HOLE CRACK AT 6:00 POSITION REPAIRED IAW ECRA 5343-01046.
DURING OPEN HOLE INSP FOUND FASTENER HOLES CRACK AT LWR CHORD AND WEB ON BS1035 LT UNDERWING LONGERON. REPAIRED THE LT BS1035 CENTER WING BOX FRONT SPAR CHORD & WEB CRACK AS PER ECRA 5710-02684 REV.
REF NR L/P: 9459062 - SPEC NO. B777-06-3-7157 - FUS EXTERNAL SKIN STA2108-STA2150 S1L-S3L FND CHAFING. FUSE EXTERNAL SKIN STA2108-STA2150 STR 1L - STR 3L SKIN REPAIRED AS PER SRM 53-70-01 REPAIR 3 FIG202 REV77 AND ECRA 5330-06425.
REF NR L/P:9459063 - SPEC NO. B777-06-3-7157 - FUSE EXTERNAL SKIN STA 2108-2150 S1R-S3R FND CHAFING. FUSE EXTERNAL SKIN STA 2108-2150 STR 1R - STR 3R SKIN REPAIRED AS PER SRM 53-70-01 REPAIR 3 FIG202 REV77 AND ECRA 5330-06425.
EMERGENCY LIGHT TEST FND L3 EMERGENCY AREA LT NO ILLUMINATE. THE BATTERY PACK REPLACED AND CONDITION CHK, TEST ''OK'' REF AMM 33-51-06-960-802 AMM 33-51-06-960-802 REV 83.
OPERATION CHK FND DR4 4EA EMERGENCY LT NO ILLUMINATE. REPLACED THE DOOR 4R BATT PACK M33408 AND C/O TEST FND EMERGENCY LIGHT ''NORMAL'' REF AMM 33-51-06-960-802 REV 83.
INTEGRATED STANDBY FLIGHT DISPLAY AIRSPEED OR ALTITUDE IS NOT CORRECT, STANDBY ALTIMETER INDICATES 370 FEET BELOW CRUISE ALTITUDE. ISFD OPS TEST PASSED IAW AMM 34-24-02. SYSTEM SERVICEABLE.
3L MED EXTERIOR EMERGENCY LIGHT IS INOP. RELAMPED BULB OPS CHECK GOOD REF AMM 33-51-04 OPS CHECK GOOD
ROW 33L OVERHEAD EMER LIGHT COVER IS MISSING. SECURED LENS COVER.
L3 DOOR & R1 DOOR UPPER EXIT SIGNS STOPPERS FOUND BROKEN. REPLACED THE SIGN STOPPERS AND CARRY OUT CONDITION CHECK FOUND NORMAL IAW AMM 33-51-01-960- 802, REV.80, AND OPERATIONAL TEST FOUND GOOD.
L4 DOOR EMERGENCY LIGHT POWER PACK M33407 FOUND LOW CAPACITY DURING CAPACITY CHECK. REPLACED THE POWER PACK. OP TESTED NORMAL IAW AMM 33-51-06-960-802, REV 80.
R4 DOOR EMERGENCY LIGHT POWER PACK M33409, FOUND LOW CAPACITY DURING CAPACITY CHECK. REPLACED THE POWER SUPPLY, OP TESTED NORMAL IAW AMM 33-51-06-960-802, REV 80.
MAIN DECK A & B ZONE PARTITIONS, LOWER EMERGENCY LIGHTS FOUND BROKEN. REPLACED THE EMERGENCY LIGHT ASSEMBLIES AND OP TESTED NORMAL IAW AMM 33-51 -05-960-802 REV 80.
SEAT 8C LOWER EMERGENCY LIGHT FOUND BROKEN. REPLACED THE EMERGENCY LIGHT ASSY AND OP TESTED NORMAL IAW AMM 33-51-05-960-802, REV 80.
R3 DOOR UPPER EXIT SIGN ARROW FOUND WRONG. REPLACED AND CHECKED, FOUND NORMAL IAW AMM 33-51-01-960-802, REV 80.
EXTERIOR EMERGENCY LIGHT AT POSITION 4L INOPERATIVE. REPLACED THE LAMP. OPS CHECKED GOOD IAW AMM 33-51-04.
EMERGENCY LIGHTS AT SEATS 19 - 22 RT & SEATS 25 & 31 LT INOPERATIVE. R & R & OPERATIONS CHECKED EMER LIGHT BATTERY & CHARGER SEAT ROW 19 RT SIDE IAW 30 0 33-51-07. RELAMPED SEAT 25 RT & 31 LT. OPERATIONS CHECKED GOOD.
ENGINE FUEL VLV L STATUS MSG ON SHUT DOWN. ALL PLUGS WERE CLEANED & RECONNECTED. RELAY K76105 WAS REPLACED IAW WD 76-21-11. WORK WAS ACCOMPLISHED IAW FIM 73-22-820 & FIM 73-24-810. TWO ENG RUNS COMPLETED WITH NO FAULTS.
ENGINE L SURGE AUTO EVENT ON SHUTDOWN CORRELATED TO 71-60431. ACCOMPLISHED FIM TASK 71- 05-819, IAW C3. NO CORRECTIVE ACTION REQUIRED.
ENGINE FUEL FILTER LT DIFF PRESS ACROSS LT FUEL FILTER APPROACHES BYPASS CONDITION. CAME ON DURING & AFTER TAKEOFF. REPLACED FUEL PRESS DIFF SW, CHECKED OK.
793 LT ENG EEC IS NOT RECEIVING 115V AC POWER CHANNEL B, OCCASIONAL NCMM MX MESSAGES 73-41221 73-51221.
THREE CB`S POPPED. REPLACED POWER SUPPLY & BATTERY, OPERATIONS CHECKED GOOD.
INTERMITTENT PA STATUS MESSAGE, WHEN PA USED FROM CABIN. REPLACED THE PASSENGER ADDRESS CABIN INTERPHONE CONTROLLER IAW MM 23-39-03-401. QUICK TEST FAULTS SDM 2-6, M23036 LT CTR ROW 22 REPLACED SDM BUT STILL FAULTS ON QUICK TEST, SUSPECT SDM WAS BAD FROM STOCK. SUGGEST INSTALLING ANOTHER SDM M23036. PACI & MULTI SDM REPLACED. NOTE PTT 1122009 OPEN IN CIRCUIT NEVER ISOLATED OR CORRECTED. IAW WDM'S 23-31-31,32 & CHECKED ALL WIRING BETWEEN SDM'S 2-5,2-6,2-7,2-8, CONFIRM GOOD GND'S. REPLACED SDM M23037, 2-7 & M23042, 2-12 IAW MM 23-31-02-401, OPERATIONS CHECKED GOOD.
NR 1 ENG IDG FEEDER CABLE SHRINK TUBING AT IDG SHOWS SIGNS OF HEAT & CRACKING. REPLACED NR 1 ENG IDG FEEDER CABLE YELLOW & BLUE PHASE ID COLOR BANDS.
EMERGENCY EXIT LIGHT LENSES MISSING ON BOTH AISLES OF UB-TO-ECONOMY PLUS CTR CLASS DIVIDER. REPLACED LENSES.
DISPLAY UNIT BLANK, BLINKS ON & OFF. CAPT ND DISPLAY INOPERATIVE. SWAP CAPT ND MR31612-562 TO LOWER EICAS DISPLAY MR31612-555. AFTER SWAP CAPT ND CHECKED OK. LOWER EICAS DISPLAY INOPERATIVE IAW MEL. REMOVED LOWER DU MR31612-562 & INSTALLED LOWER DU MR31612-658 IAW AMM. INSTALLATION TEST PASSED.
PACK MODE RT SMOKE & ELECTRIC SMELL IN CABIN. FOUND DURING TROUBLE SHOOTING ACM PACK RT AT FAULT. THIS CAUSED SMOKE IN CABIN. AFTER ACM PACK RT REPLACED RUN ALL PACKS 1.0 HR. NO SMOKE OR ELECTRIC SMELL IN CABIN NOTED. SYSTEM OK FOR SERVICE.
ENGINE ELECTRONIC ENGINE CONTROL MODE L MESSAGES 73-61011. TROUBLESHOOTING FOUND ENGINE RELAY UNIT M73005 AT FAULT. NEED TO REPLACE EMERGENCY RELAY UNIT, IAW FIM 71-11 TASK 812, FIM 77-11 T812. ACTIONED & LEFT ENGINE EMERGENCY RELAY UNIT REPLACED IDLE RUN NO FAULT. ELECTRONIC ENGINE CONTROL STATIC & PROBE HEAT TEST VIA MAT PASSED.
RIGHT ENGINE WOULD NOT SHUT DOWN & FUEL FLOW DID NOT DECREASE TO ZERO WHEN FUEL LEVER MOVED TO CUTOFF. STATUS MESSAGE ENGINE FUEL VALVE RT. HAD TO PULL ENGINE FIRE HANDLE TO SHUT DOWN ENGINE. ENGINE DID NOT SHUT DOWN IMMEDIATELY AFTER FIRE HANDLE WAS PULLED. ENGINE CONTINUED TO RUN AN ADDITIONAL 20-30 SECONDS AFTER FIRE HANDLE WAS PULLED.
ELECTRICAL DC STANDBY POWER SYSTEM FAILED SELF CHECK. , FOUND STATIC INVERTER WAS BAD. REPLACED IAW AMM, TESTED OK.
APU SHUTDOWN ON WAY TO GATE.
NR 2 ENGINE IGNITION STATUS MESSAGE, RETURNED TO FIELD. REPLACED R2 EXCITER & THE RT IDG.
LEFT ENGINE ELECTRONIC ENGINE CONTROL IS IN THE ALTERNATE CONTROL MODE DUE TO A CONTROL SYS FAULT. REPLACED ENGINE RELAY UNIT.
STATUS MESSAGE "ENGINE FUEL VALVE RT" WITH MESSAGE 73-60212. CHECKED WIRING IAW WDM 76-21-71, PG 1 BETWEEN D71024P TO D71074J AND DM76001C, NO DAMAGE FOUND, VOLT APPROXIMATELY 26-28V AND CLEANED ALL CONNECTOR. PERFORMED VISUAL INSPECTION FOR MODULE ASSY W0625 AND ALL CORE WIRING HARNESS, AND REPLACED FUEL CONT RELAY K76207. THEN MESSAGE WENT AWAY.
RT RADIO TUNING PANEL RT VHF GREEN LIGHT OUT. REPLACED RT RADIO TUNING PANEL, OPS CHECKED OK.
NR 2 ENG FUEL, HYD SUPPLY LINE FIRE BLANKET DAMAGED. NR 2 ENGINE HYD HEAT BLANKET HAS BEEN REPLACED.
AFTER SHUTDOWN, NR 2 ENGINE WAS SMOKING HEAVILY. TRIED TO START ENGINE WITH NO LIGHT OFF. STATUS MESSAGE "ENG FUEL VALVE R" DISPLAYED. RIGHT FUEL CUTOUT SWITCH REMOVED FOR REPINNING OF NEW SWITCH.
ENGINE HAS INTERMITTENT EEC MODE FAULT CAUSED BY LOSS OF HEAT POWER (MESSAGE 73-61011). WIRES AND CONNECTORS ALL CHECKED GOOD IAWFIM 73-21 TASK 801, NO FAULTS OR DISCREPANCIES NOTED.
RT WING FLAPERON MISSING THREE FEET OF BULB SEAL ON THE LOWER OUTBD SIDE. COMPLIED WITH CDL. REPLACED FLAPERON SEAL.
LEFT WING LOWER PANEL 561SB HAS LIGHTNING STRIKE. REPAIRED.
STATUS MESSAGE, OVERHEAT CIRCUIT R1. ISOLATED NR 2 FIRE HARNESS. MEGGERED WIRE SHORTED TO GROUND. INSTALLED WIRES, NO MESSAGES. REPLACED WIRES W0656-1001R-16 AND W0656-1002R-16 IAW 26-11-21 SWPM 20-10-13.
APU GEN WON`T GO ONLINE. REPLACED APU GCU PER AMM AND AUX PWR BREAKER (C24335). INSTALLATION TEST PASS. SOFTWARE CONFIG CHECKS WITH PROPER SOFTWARE. NO FAULTS NOTED.
ENG EEC C1 R DISPLAYED ON STATUS PAGE. DO NOT USE THERMOCOUPLE 280-4257, THE CORRECT PW4090 PCN IS 223-1593. REPLACED 'B' CHANNEL THERMOCOUPLES ON THE 2.9 START STABILITY BLEED VLV 2 EACH AT 2 AND 10 O'CLOCK POSITION ON NR 2 ENGINE IAW AMM.
FIRST OBSERVER`S RADIO POSITION MALFUNCTIONED. REPLACED AUDIO MANAGEMENT UNIT PER AMM, TEST PASSED ALL AUDIO AND COM. OPS CHECKED GOOD.
NR 3 COMM PANEL TRANSMITTER SWITCH STICKS. REPLACED AMU, CHECKED OKAY.
NR 2 ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILED. FOUND CHAFED WIRE HARNESS BETWEEN LWR FWD AND LWR AFT LOOPS. REPLACED FIRE LOOP HARNESS AND FIRE TESTED OK.
LEFT ENGINE OVERHEAT DETECTION CIRCUIT 2 FAILED. MEASURED LEFT ENGINE LOOP 2 INDIVIDUAL ELEMENT CORE RESISTANCE AND MEGGER RESISTANCE TO GROUND, FOUND TO BE WITHIN LIMITS OF FIMMAN 26-11-810. FOUND CHAFED WIRE HARNESS AT RIGHT SIDE ENGINE, 2 FT FWD OF 'LWR AFT LOOP' UPPER END - FWD SIDE RACEWAY, UNDER FWD MOST CLAMP. REPLACED FIRE LOOP HARNESS AND FIRE TESTED OK AND NEW MESSAGES DISPLAYED.
DURING IDLE LEAK CHECK OF NR 2 ENGINE FOUND TURBINE CASE COOLING AIR VALVE ACTUATOR LEAKING FUEL. STARTED TO REMOVE TCC ACTUATOR. REPLACED TCC ACT PER MM75- 24-05, ALL CHECKED NORMAL.
BLEED FAMV L LEFT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED OR LEFT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610200 LATCHD CL MODE MSG-3610531 LATCHD DC MODE MSG-3610190 LATCHD DC MODE MSG-3610190 LATCHD DC MODE. OPEN DEFERRED SEE DF329. REPLACED FAMV VALVE PER MM 36-11-16 PG 401 OPS CK'D NORMAL. ACP ENG RUN OPS CK'D NORMAL CLEARED FAULT.
FMC L EICAS MESSAGE-CPM ACMF LEFT AIMS HAS NO OUTPUT. REPLACED CPM-ACMF IN LEFT AIMS CABINET TROUBLESHOOTING CONTINUES.
STATUS MSG PASS ADDRESS. UNABLE TO DUPLICATE PROBLEM AND NO ACTIVE FAULTS NOTED. DUE TO HIS WITH MSG 23-03249, REPLACED M23040 PRECAUTIONARY. ACP CABIN PROGRAMMING, SYSTEM TESTED NORMAL.
NR 1 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 433CL CUTOUT. REPAIRED IAW ECRA 5431-01061.
NR 2 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 443CL CUTOUT. REPAIRED IAW ECRA 5431-01061.
WEAR DAMAGE ON NR 2 PYLON AFT FAIRING HEATSHIELD GAP COVER STRIP P/N 313W3829-3 DAMAGE AREAS CONSIST OF ABRASION WEAR WHERE THE STRIP IS WORN THROUGH IS FULL DEPTH. THE FIRST DAMAGE AREA IS LOCATED 7" O/B FROM THE INBOARD EDGE OF THE GAP COVER STRIP AND MEASURES 1.5" IN LENGTH X 3-16" IN DEPTH. THE SECOND DAMAGE AREA IS LOCATED 11" O/B FROM THE INBOARD EDGE OF THE GAP COVER STRIP AND MEASURES 4.75" IN LENGTH X 1-4: IN DEPTH. SRM 54-50-70, FIG 103 DOES NOT PERMIT DAMAGE TO EXCEEDS 2.00" IN LENGTH. THE HEAT SHIELD GAP COVER STRIPS ARE MADE OF TITANIUM ALLOY T1-6AL-2SN-4ZR-2MO.
RIGHT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM IS OPERATING WITH REDUCED REDUNDANCY. STATUS MESSAGE 01- ACTIVE CLIMB INTERMITTENT; 2.9 START BLEED VALVE TC PROBE (R ENG, CH B) TEMPERATURE SIGNAL IS OUT OF RANGE. DB- ELECTRONIC ENGINE CONTROL (R ENG, CH B) MSG02- NOT ACTIVE DESCENT INTERMITTENT; 2.9 START BLEED VALVE TC PROBE (R ENG) TEMPERATURE SIGNAL IS OUT OF RANGE. DB- ELECTRONIC ENGINE CONTROL (R ENG, CH B) MSG03- NOT ACTIVE DESCENT INTERMITTENT; 2.9 START BLEED VALVE TC PROBE (R ENG) TEMPERATURE SIGNAL IS OUT OF RANGE. RAN FIM TASK 75-32-TASK 827 MESSAGE CLEARED. PER 'MAT' MESSAGE CLEARED WITHIN 20 SECONDS, NO FURTHER ACTION REQUIRED.
FIX PAGE WILL NOT DISPLAY CORRECT BEARING. REPLACED HDG REF SWITCH.
ACARS DATA MODE INOPERATIVE. REPLACED CENTER VHF, GROUND TESTED GOOD.
NR 1 ENGINE IDG TERMINAL ENDS BLUE AND YELLOW TEFLON IDENT SLEEVES ARE DETERIORATED. REPLACED INSTALLATION ON TERMINALS.
APU BLEED AIR MESSAGE. REPLACED IGV ACTUATOR DUE TO APU BLEED AIR MESSAGE. REPLACED IGV ACTUATOR FROM START TO ITEM 3F.
NR 2 PYLON HEAT SHIELD GAP COVER STRIP (2ND STRIP COUNTING FROM FWD TO AFT) IS CRACKED AT TWO PLACES (ONE CRACK IS LOCATED AT A PREVIOUS REPAIR). REMOVED DAMAGE & ACP HFEC INSPECTION REF 777MT 54-UA2 DAMAGE 1.28-32L BY 1-4 DEEP.
L RAM AIR DOOR FAULTS. ACFT TEMP CONTROL SEEMS TO BE ADJUSTING ITSELF TEMP CONTROL IS INACCURATE THIS IS FOR THE WHOLE ACFT. LT RAM AIR INLET FAULTS AND STOPS TEST. LT RAM AIR INLET ACTUATOR LOCKED IN THE FULL OPEN AND CONNECTOR PLUG REMOVED. REPLACED LT CTC WOULD NOT DRIVE RAM AIR ACT DURING SYS TEST. SWAPPED WITH RT CTC. PROBLEM FOLLOWED LT CTC. RETURNED UNITS TO ORIGINAL POSITION. REPLACED AND TESTED LT CTC OK PER MM.
CREW REPORT RAM AIR INLET DOOR MSG DISPLAYED. ACFT RETURNED TO GATE. ITEM DEFERRED PER MEL. RAM AIR DOOR LOCKED OPEN FOR 895507. REPLACED LT RAM AIR INLET ACTUATOR, ALL OPS CK'D NORMAL.
CREW REPORT AFTER TAKEOFF TRIM STUCK AT 6.0 UNITS. EXCESSIVE FORWARD FORCE TO KEEP NOSE DOWN. REPLACED CAPT PITCH TRIM SWITCH PER MM. ACCOMPLISHED RII INSPECTION, SATIS.
CREW REPORT VERBALLY ELECTRICAL BURNING ODOR IN MID GALLEY. CREW REPORTED SMELL DISAPPEARED UPON GALLEY PWR REMOVAL. REMOVED C-MS CHECKED ALL WIRING IN AFT SECTION OF GALLEY NO EVIDENCE OF BURNING, CHECKED C-B PANEL AND ASSOCIATED 3 PHASE WIRING ALL INTACT. OPENED CEILING AREA AND INSPECTED SURROUNDING AREA WITH CHILLERS IN OPERATION ALL OK.
CARGO FIRE AFT ARM SWITCH NO LIGHT TEST. FIRE TEST PASSES OKAY. REPLACED SWITCH MODULE & RESET ACFT POWER & CHECKED NORMAL.
FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. STATUS MESSAGE 2710306 ACTIVE ER MODE. REPLACED RIGHT FLAPERON INBD PCU, NO HELP. CONNECTOR PIN 17 HAS CORROSION. REPLACED CABLE ASSY FLAPERON POWER. ACCOMPLISHED FLAPERON RIGGING PER MM. RIGHT FLAPERON ACTUATOR. CONFIDENCE TEST PASSED.
FLIGHT CONTROL SYSTEM ADVISORY. ON ARRIVAL, FOUND MESSAGE 27-1030 6 AND NOT ACTIVE. CARRIED OUT GROUND TEST, TEST FAILED. ACCOMPLISHED FIM 27 -11 TASK 906. REPLACED ACE-L2 NO HELP, BACK TO ORIGINAL. ACCOMPLISHED WIRE CHECK BETWEEN D4422J AND DM27210, CHECKED OK. ALSO CLEANED CONNECTOR. EXERCISED FLAPERON AND CHECKED FLAPERON OPERATION. AFTER EXERCISED MESSAGE NUMBER CHANGED TO 27-11305. CARRIED OUT PRIMARY FLT CONTROL SYSTEM TEST, TEST PASSED AND MESSAGE DISAPPEARED. FOUND NO EX FAULT.
RIGHT HF TRANSMITER INOPERATIVEF. RECEIVES OK. RADIO UNABLE TO HEAR RT HF TRANSMISSION. REPLACED RT HF COUPLER, GROUND TEST PASSED. TRANSMIT AND RECEIVE GOOD.
PACK MODE R RIGHT PACK AIR CYCLE MACHINE HAS FAILED, OR RIGHT ECONOMY COOLING VALVE FAILED OPEN, OR BOTH RIGHT CONDENSOR INLET TEMP SENSORS FAILED. RIGHT PACK IS OPERATING IN A NON-NORMAL MODE (HEAT EXCHANGER ONLY COOLING MODE). ADVISORY -COMPLIED W MEL 2151S. MSG IS COND SENSOR TEMP RT MSG# 21-23402. REPLACED LOW LIMIT VALVE PER MM, OPS CHECK NORMAL.
LIGHTNING STRIKES TO A/C. LIGHTING STRIKE DAMAGE. 3 FASTNERS IN A ROW DAMAGED AND OUT OF LIMITS PER SRM. SMC 44, SMC 44 AND SMC 45. NO RESTRICTIONS, LINE CREW OKAY. ACCOMPLISHED INSPECTION NO DISCREPANCIES NOTED. IN REFERENCE TO LIGHTNING STRIKE FORWARD OF LEFT WING, APPROX 18 RIVETS HAVE BEEN REWORKED AND PRIMED AND PAINTED. TOOK CORRECTIVE ACTION ON LIGHTNING STRIKE AT BS 533 & STR 27L, BS 538 & STR 27L, BS 540 AND STR 27L, BS 722 AND STR 25L, BS 528 AND 2" ABOVE STR 28L, BS 544 AND 2" ABOVE STR 28L, BS 709 AND 4" ABOVE STR 25L, BS 676 AND 5" ABOVE STR 26L, BS 669 AND 2" ABOVE STR 26L, BS 671 AND 2" ABOVE STR 26L, BS 524 AND 2" ABOVE STR 28L, BS 571 AND 6" ABOVE STR 27L, BS 524 AND 2" ABOVE STR 28L, BS 544 AND 2" ABOVE STR 28L. FASTENER TO BE INSPECTED EVERY 1000C AND BLIND FASTENER TO BE REPLACED BEFORE 16000C MF8275 CREATED TO MONITOR LIGHTNING STRIKE DAMAGE TO SKIN AT STA 709 AND 4" ABOVE STR 25. DRILLED OUT DAMAGE TO SKIN, INSP ACCOMPLISHED NDT OF HOLE, INSTALLED BLIND FASTENER. FASTENER TO BE REPLACED BEFORE 16000C MF8276 CREATED TO MONITOR
ACCOMPLISHED NR 1 ENG BOROSCOPE OF HPT BLADES, FOUND 1ST STAGE HPT BLADES WITH MATERIAL BREAK THROUGH INTO INTERNAL CAVITY CONCAVE SIDE AREA 'B' APPROX .273 SQ IN EXCEEDING LIMITS OF .0125 SQ IN PER MM. REPLACED ENGINE.
LEFT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED OR LEFT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. DEACTIVATED LT ENG FAMV PER MEL REQUIREMENTS. REPLACED FAMV PER MM, OPS TESTED GOOD.
WEAR DAMAGE ON NR 2 PYLON AFT FAIRING HEAT SHIELD GAP COVER STRIP P/N 313W3829-3 (IPC 54-54-02-007,ITEM 270) DAMAGE AREAS CONSIST OF ABRASION WEAR WHERE THE STRIP IS WORN THROUGH IST FULL DEPTH. THE FIRST DAMAGE AREA IS LOCATED 7 INCHES O/B FROM THE INBOARD EDGE OF THE GAP COVER STRIP AND MEASURES 1.5 INCH IN LENGTH X 3-16" INCH DEPTH. THE SECOND DAMAGE AREA IS LOCATED 11 INCHES O/B FROM THE INBOARD EDGE OF THE GAP COVER STRIP AND <<104747 BY- 104747 MEASURES 4.75 INCHES IN LENGTH X 1-4: INCH IN DEPTH SRM 54-50-70, FIG 103 DOES NOT PERMIT DAMAGE TO EXCEEDS 2.00 INCHES IN LENGTH. THE HEAT SHIELD GAP COVER STRIPS ARE MADE OF TITANIUM ALLOY T1-6AL-2SN-4ZR-2MO.^10OCT ORD INF- :THIS TIME LIMITED REPAIR IS ACCEPTABLE FOR 12 MONTHS FROM 10-10-2011 TO 10-10-2012 AT WHICH TIME THE COVER STRIP MUST BE REPLACED REF: AD 2006-190-12^11OCT SFO INF- :WILL NEED AN EST. 3 TO4 SHIFT SLOT TO REPLACE STRIP. WILL NEED TO REMOVE ENG EXHAUST NOZZLE AND DISASSEMBLE HEAT SHIELD ASSY FOR ACCESS.
LEFT SDU MALFUNCTIONED. REPLACED SATELLITE DATA UNIT. OPS CHECKED NORMAL.
LEFT OUTBOARD TE FLAP DAMAGED JUST INBOARD OF NR 1 CANOE. REPAIRED REF SRM, REPAIR NR 12 AND SRM 70-0.
ELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE) - ADVISORY CREW COMMENTS: DISCONNECTED GEN DRIVER. PROG TEXT: - ITEM ROLLED FORWARD. EICAS MSG ELEC GEN SYS R. FOLLOWED MEL PROC. CHECKED RT IDG AND NO DAMAGE AND OIL LEAK FOUND. IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED PER MEL. REPLACED RT IDG PER MM.
PRIOR TO DEPT, CTR FUEL QTY DROPPED 20K LBS. RESET CB FOR PROCESSOR AND QTY READS OK BUT DENSIOMETER READING STILL BLANK. VERIFIED QTY WITH STICKS. FUEL UPLIFT READINGS OK. RPL CTR TANK DENS PER MM. NEEDS FQPU OPS CHECK AND FQIS OPS CHECK. PERFORMED FQIS OPS CHK, CHECK GOOD. REF DF948, RECOMMEND REPLACING PROBE NR 3 IN RT CTR TANK. M28249 TANK UNIT SIGNAL IS OUT OF RANGE. RPLC'D PROBE NR 3 IN RH CTR TANK. NEED TO ACC TASK 28-41-00-710-801 & 28-41-00-710-802. PERFORMED FQIS OPS CK REF MM, CHKS GOOD.
APU WON'T START PRIOR TO DEPARTURE. APU SPEED DID NOT REACH 7 PERCENT, CAUSED AUTO SHUT-DOWN, MUST ACCOMPLISH FIM 49-40 TASK 812, A BATTERY DISCHARGE OF APPROX 100 AMPS IS NECESSARY FOR ELECT. STARTER MOTOR TO TURN ABOVE 7 PERCENT SPEED, IF ELECT. STARTER MOTOR GETS LESS THAN 100 AMPS, THEN THE APU MAY NOT REACH 7 PERCENT SPEED AND THE CAUSE OF THIS MAINT. MESSAGE TO SHOW IS AN ELECTRICAL FAULT. START FIM 49-40 TASK 812 AT PARA "C".
LEFT ENGINE START VALVE MESSAGE. VALVE IS DEFECTIVE. REPLACED START VALVE PER MM. OPS NORMAL.
GENERATOR SYSTEM RT STATUS MESSAGE, IDG DROPPED OFF LINE, DISCONNECTED IDG PER FM. CMC FAULT SHOWS IDG RIGHT FREQUENCY IS LOW. REPLACED NR 2 IDG PER MM. RAN ENGINE OPS CHECKED OK. IDG DISCONNECTED AND RECONNECTED CHECKED OK.
AFTER PUSHBACK, CREW STATES RT ENG FUEL VLV MSG DISPLAYED. TRIED 2 START ATTEPMTS, NO JOY. REPLACED NR 2 ENG FMU, NO HELP FOR MSG 73-60212, THEN HAD CORRELATED SPAR VLV MSG 28-14002, REPLACED R-RNG SPAR VLV ACT, NO HELP, REPLACED K28222 IN P101, R-ENG STARTED 2X IN A&B CHANNEL, REF FIM28-22TSK841, OP CHECKED GOOD. NO FAULTS, NO LEAKS.
RT ELECTRICAL EQUIPMENT COOLING AIR SUPPLY FAN FAILED OR INOPERATIVE. REPLACED RT EQUIPMENT COOLING SUPPLY FAN, ACCOMPLISHED MAT CMC EQUIP COOLING TEST, TEST PASSED.
FOUND EVIDENCE OF LIGHTNING STRIKE CONDITION HITTING SEVERAL RIVETS AT RT SIDE OF FUSELAGE BETWEEN STA 298 AND 487 FROM STRINGERS S35R TO S39R. 28 RIVETS WERE IDENTIFIED WITH BURNING SIGNS. THERE ARE 2 GROUPS OF 4 ADJACENT RIVETS, 1 GROUP OF 6 ADJACENT RIVETS AND 4 GROUPS OF 3 ADJACENT RIVETS. THE REMAINING RIVETS ARE DISTRIBUTED IN THE MENTIONED AREA. BURNISHED DAMAGE AS NEEDED AND PRIMED REMOVED DAMAGED FASTENERS AS NEEDED, WILL REQUIRE HFEC AND OVERSIZE BEFORE SOLID FASTENERS INSTALLED, REF SRM 53-00-01, REPAIR 8.
LIGHTNING STRIKE DAMAGE TO SKIN AND RIVETS ON LEFT & RIGHT SIDE OF FUSELAGE. ALSO HAS DAMAGE TO LT FWD NOSE GEAR DOOR. REPAIRED IAW SRM 53-00-01, REPAIR 8. LEFT FWD NLG DOOR REPAIRED REF SRM 52-80-01.
RT STAB TRIM INDICATOR IS BLANK. REPLACED INDICATOR PER MM, SYS CHECKS GOOD PER MM.
HF RADIO - TRANSMISSION PROBLEM. RIGHT RADIO INOP. RT HF IS SLOW TO TUNE FREQ ORDERED COUPLER M23202 (530-9045) TO B29 PARTS LOCATION. REPLACED RIGHT COUPLER, CHECKED OKAY.
OFFSIDE TUNING LT-DAMAGED CTR VHF PANEL. REPLACED TUNING PANEL CNTR REF MM. OPS NORMAL.
ELEC BACKUP SYS STATUS. DUE TO REPETITIVE REPORTS OF 'ELEC BACKUP SYS' STATUS MESSAGE WITH CORRELATED MESSAGE. IF NO FAULTS NOTED, REPLACE BUG CONVERTER (M24008) PCN 566-9012 & IF NECESSARY, CCB (K24202) PCN 566-0547. IAW MM REPLACED WITH NEW BUG CONVERTER & CCB (K24202). RAN BOTH ENG IAW JRH, OPS CK FINE AND INDICATION NORMAL. NO DEFECTS NOTED.
RAMP REPORTED, LT SIDE GUIDE HAS 1.2 FT SCRATCH FROM STA 575 AND HALF IN CRACK AT STA 590 IN FWD CARGO. THIS SIDE GUIDE RAIL IS LT SECOND RAIL FROM FWD. CKD AND NEED SHEET METAL REPAIR OR REPLACE THE WHOLE SIDE RAIL ASSY LT SIDE STA 540-640. REPLACED RAIL ASSY.
EMERGENCY LIGHT AT SEAT 1F, FWD LIGHT IS OUT. REPLACED LIGHT ASSY. OPS CHECK GOOD.
EMERGENCY LIGHT AT SEAT 2F, AFT LIGHT IS OUT. REPLACED LIGHT ASSY. OPS CHECK GOOD.
WXR SYS, WXR DISPLAY IS NOT PRESENT WHEN WXR SELECTED ON EFIS CONTROL PANEL. STATUS MSG03- ACTIVE CRUISE INTERMITTENT; WXR ANTENNA DRIVE IS NOT CONNECTED OR FAILED. DB- WXR TRANSCEIVER (RT) MSG04- NOT ACTIVE CRUISE INTERMITTENT; WXR ANTENNA DRIVE IS NOT CONNECTED OR FAILED. MSG-3444031 INACTV ER INTER MSG-3444031 INACTV ER INTER MSG-3444032 ACTIVE ER INTER MSG-3444032 INACTV ER INTER. UPON ARR. BOTH SYS TEST FAIL. REPLACED ANTENNA DRIVE ASSY. TESTS OK IAW MM.
DOOR 4L, COVER FELL OFF EMERGENCY LIGHT ON RT SIDE OF DOOR. SECURED COVER.
OVEN R31 STARTED TO OVERHEAT DURING THE PREPARATION OF THE MEAL SERVICE, EMITTED AN ELECTRICAL ODOR FLIGHT ATTENDANT SHUT OVEN DOWN IMMEDIATELY AND PULLED THE CIRCUIT BREAKER FOR THAT OVEN. REMOVED OVEN. CHK'D EVIDENCE OF ODOR FOUND NONE. DEACTIVATED OVEN PER MEL CARD. OVEN WAS RECENTLY REPLACED ON OCT16. CHECKED WIRE BUNDLE BEHIND PANEL GALLEY'S POWER CONTROL, NO DAMAGE FOUND. SUSPECTED CB-C004 AT FAULT. REPLACED OVEN AND MISSING BOLT, CHECKS OKAY.
RIGHT F/O WINDOW 1 WINDSHIELD HAS ARCING ON LOWER RT CORNER OF WINDOW ON BUS BAR. REMOVED WINDOW. INSTALLED NEW WINDOW.
WINDSHEAR SYS EITHER PREDICTIVE OR REACTIVE WINDSHEAR ALERTING FUNCTIONS ARE FAILED SUCH THAT WINDSHEAR ALERTING CAPABILITY IS REDUCED OR NOT AVAILABLE. A REACTIVE WINDSHEAR FAILURE WILL ONLY SET THE MESSAGE WITH THE REACTIVE WINDSHEAR OPTION ACTIVE. ADVISORY MSG-3444032 ACTIVE DC HARD MSG-3444031 ACTIVE AP HARD. REPLACED WEATHER RADAR ANTENNA ASSY. GROUND TEST PASS FOR BOTH.
CABIN TEMP PROBLEM, FLIGHT DIVERTED. REPLACED LEFT PACK TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE (PRSOV) REF AMM AND LEFT CABIN TEMPERATURE CONTROLLER (CTC) REF AMM.
C1 HYD ACMP CONNECTOR DM29304A HAS EVIDENCE OF SOCKET ARCING. REPLACED CONNECTOR AND SOCKETS. REPLACED PRESSURE TRANSDUCER FOR C1 ELECTRIC PUMP. CHECKS GOOD.
ROW 3E AFT EMERGENCY LIGHT INOP. REPLACED EMERGENCY LIGHT. OP CK NORMAL.
NR 2 ENG HAS METAL FINES ON ALL CHIP DETS IAW LM. NR2 ENGINE REPLACED IAW MM.
NR 2 ENGINE PRECOOLER CRACKED ALONG INBD, BOTTOM EDGE. STARTED TO REMOVE PRECOOLER. ACCOMPLISHED UP TO STEP NR 2. NEED TO COMPLETE FROM STEP NR (11) PG405. ACCOMPLISHED FROM MM36-11-15, PG404 STEP (11) THROUGH PG416 STEP 3(G)4. ACCOMPLISHED FROM PG416 STEP 3 H TO TO END, NO LEAK FOUND.
LOW SIGNAL FROM SATCOMM RFU ORDERED NEW RFU FROM DEN SATCOMM HAS LOTS OF HISTORY. REPLACED RADIO FREQUENCY UNIT. SYS LOGGED ON OK.
APU BATTERY, APU BATTERY FAILURE. STATUS BATTERY CHARGER PREVIOUSLY REPLACED. NO HELP. BATTERY DOES NOT HOLD CHARGE, NEEDS RPL, ON ORDER. REPLACED APU BATTERY, OPS NORMAL.
BATTERY CHARGER APU APU BATTERY CHARGER FAILURE. STATUS MSG01- ACTIVE TAXI OUT MODE DEPENDENT; APU BATTERY IS WEAK. DB- ELMS P310 ELECTRONICS UNIT MSG-2413047 ACTIVE TA MODE. REPLACED APU BATTERY CHARGER.
SAT VOICE LOST SATCOM VOICE SYS. REPLACED SATELLITE DATA UNIT AND HPA-LGA. INSTALLATION TESTS NORMAL. ACCOMPLISHED SATCOM OP CK, OPS NORMAL.
1E EMERGENCY LIGHT MISSING. REPLACED BROKEN EMERGENCY LIGHT, OP CHECKS GOOD,
2E EMERGENCY LIGHT INOP. SECURED CONNECTOR ON LIGHT ASSY. LIGHT OP CHECKS GOOD.
THE FASTEN SEAT BELT SIGNS FLASH ON AND OFF IN 1ST AND BUSINESS CLASS AT THE SAME TIME THE INDICATOR PANEL BETWEEN LAV 100 AND 100 FLASHES WHEN F/A'S ATTEMPT A RESET AT THE 1L CACP PANEL IT IS INDICATED THAT THERE IS A TEMPERATURE CONTROL FAILURE AT ROWS 11-13 THE CACP PANEL FLASHES 'FAIL' IN ORANGE LETTERS AND THE SYS IS LOCKED. AFTER AC BOOST UP, CANNOT GET INTO CSCP MAIN PAGE. REPLACED CSMU AND CONFIRM NO MORE FLASHING LIGHT FOR FASTEN SEAT BELT AND CACP DID NOT INDICATED FAIL. CACP IS WORKING FINE.
DOOR FOR 02 MASKS AT SEATS 34 CDEFG HAS BROKEN HINGES. DOOR IS SECURED CLOSED. NEED TO REPLACE BOX ASSY. REPLACED BOX ASSY AND PERFORMED DROP TEST. OP CHKS GOOD.
EICAS MSG, FLT CONT SYS & SPOILER. REPLACED NR 11 PCU AND ADJUSTED. GRD TEST PASSED AND NO FAULT ON THE MAT. OPS CHECKED OKAY. REPLACED ACE-L2 DUE TO "FLT CONT SYS" AND "SPOILER" MSG DISPLAYED. ACE CHECKED OKAY.
RIGHT AFT LAV LIGHT HOT/SMOKING. FOUND MIRROR LIGHT SOCKET BURNED OUT IN 4R LAV, PULLED C/B J7 ON P320 FOR LAV LIGHT LEFT AND LAV 1L FWD CTR, 2L, 3L FWD AND 4R AVAILABLE DOME LIGHT ONLY. CONFIRMED NO POWER FOR AFFECTED LAVATORY & COVERED INSULATION TAPE OVER 4R LAV MIRROR LIGHT SOCKET. REPLACED BAD SOCKET, ALL GOOD.
EXIT SIGN COVER FELL OFF AT DOOR 4L. FOUND ALL EMERGENCY LIGHT LENS AT DOOR 4L SECURED.
SEAT 3F AFT EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP ASSY, OPS CHECK NORMAL.
ENG IGNITER L1 LEFT ENGINE FAILED TO IGNITE USING IGNITER 1. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; IGNITION SYSTEM NR 1 (L ENG) FAILED TO LIGHT ENGINE. DB- ELECTRONIC ENGINE CONTROL (L ENG, CH B) MSG-7461491 INACTV ES MODE. REPLACED NR 1 AND NR 2 IGNITER AND TESTED NORMAL.
2EA ADJACENT EMERGENCY LIGHTS ON SEAT 3F ARE INOPERATIVE. REPLACED LIGHT ASSY AND SECURED HARNESS. CHECKS GOOD.
EXTERIOR EMERGENCY LIGHT BY DOOR 1R IS INOPERATIVE. RELAMPED, OPS NORMAL.
EMERGENCY LIGHT ON SEAT 38C IS INOP. RELAMPED AND REPLACED BROKEN LENS COVER, OPS NORMAL.
DOOR 1L EXTERIOR EMERGENCY EXIT SLIDE LIGHT IS INOP. RELAMPED, OPS CHECK OKAY.
SPOILER MSG DISPLAYED-CMC MSG1&2. SUSPECT NR 3 SPOILER ACT OR CABLE. FOUND CABLE ASSY CONNECTOR SHORTING INTERNALLY AT THE RECEPTACLE. NEW RECEPTACLE ON HAND. INSTALLING PART. REPLACED NR 3 OUTBOARD SPOILER PCU. ACP INSP OF SPOILER PCU INST. NO DEFECTS NOTED. OPS CHECK OKAY.
"FLIGHT CONTROL SYS" STATUS MESSAGE IS DISPLAYED. FAILS ACE MONITOR GROUND TEST MSG27-13007. REPLACED RT ACE-NO HELP. PERFORMED ALL STEPS FOR FIM 27-02 TASK 809 AND IT STILLS FAILS GROUND TEST. REPLACED R-ACE WITH A KNOWN GOOD ACE FROM AC2982. NO HELP, REINSTALLED OLD UNIT, TRIED DICON APU AND MAIN BATTERY, NO HELP FOLLOW MT27-016-R1 UP TO STEP 11, PG 4. REPLACED ARINC-629 COUPLER B27132 (ACE-R). FLT CONTROL SYS" STATUS MSG. CLEARED & PRIM FLT CONTROL SYS - ACE MONITORS GRD TEST - PASS. ALSO REPLACED CTR-ACE.
SEAT MOUNTED EMERGENCY LIGHT AT 2E INOP. SECURED CONNECTOR, OPS CHECKS OKAY.
OVERHEAD EMERGENCY LIGHT INOP AT 36B.
FOUND NR 3 BEARING VENT TUBE BROKEN NR 1 ENG. REPLACED TUBE.
APU CONTROL STATUS MESSAGE. FOUND METAL IN APU. FOUND OIL PUMP BEARING FAILED.
BOTH EMERGENCY LIGHTS OUT ON SEAT 2F. BOTH LIGHTS INOP ON SEAT 2F. REPLACED LAMP, TESTED GOOD.
NR 2 IDG LEAKING FROM CASE. IDG FOUND LEAKING. REPLACED NR 2 ENG IDG, OPS & LEAK CHECKS GOOD.
APU EMITS SMOKE FROM TAIL PIPE. OIL QTY RAPIDLY DROPPED TO ZERO. TURBINE BLADE TIP DAMAGE ON OLD APU. REPLACED APU. OPS NORMAL.
SIGNS OF OIL LEAK FROM NR 1 ENGINE. FOUND LEAK FROM FUEL SERVO HEATER TRANSFER TUBES AT BASEPLATE. REPLACED TRANSFER TUBES O-RING SEALS AND REFITTED FUEL SERVO HEATER. ACP'D DRY MOTOR AND NO LEAKS APPARENT. ACP'D IDLE RUN AND ALL OPS GOOD. NO LEAKS APPARENT.
LIGHT COVER ON THE AFT SIDE OF DOOR 4L IS MISSING. *S/D* SUSPECT IMPROPERLY INSTALLED. REPLACED LIGHT COVER. AC OK FOR SERVICE.
EMERGENCY LIGHTS ON AFT END OF SEATS 2E & 3E ARE INOP. *S/D* SUSPECTED FAULTY LAMPS. REPLACED SEAT LIGHTS, OP CHECKED OK. AC OK FOR SERVICE.
FUEL PRESSURE PROBLEM. AFTER TROUBLE SHOOTING FOUND FAULTY SIGNAL CONDITIONING CARD. REPLACED SIGNAL CONDITIONING CARD PER MM24-09-00 ALL OPS NORMAL. ACFT OK FOR SERVICE.
RT TANK QTY INCREASES 300 LBS EVERY 10 MINUTES WITH CENTER TANK PUMPS ON. OCCURS IN NORMAL CONFIGURATION, JUST CENTER TANK RT AND LT PUMPS ON. REPLACED FWD RT MAIN DISCHARGE CHECK VALVE. PROBLEM REOCCURRED. RPL'D L-H JETTISON ISO VALVE ACTUATOR. OP'S CHK OKAY.
RIGHT TANK QTY INCREASES 300 LBS EVERY 10 MINUTES WITH CENTER TANK PUMPS ON. OCCURS IN NORMAL CONFIGURATION, JUST CENTER TANK RIGHT AND LEFT PUMPS ON.
F/A'S REPORTED SCREECHING SOUND AND SMOKE ODOR IN 1ST CLASS. CMC INDICATED AN OVERHEAT OF THE EQUIP COOLING VENT FAN. REPLACED COOLING VENT FAN PER MM21-27-20 AND OPS CHECKED GOOD. AC OK FOR SERVICE.
FIRE BOTTLE FOR FWD PIT, 1A, AFT CONNECTOR WILL NOT INSTALL ON BOTTLE. REPLACED BOTTLE. OP CHECKS OKAY.
2E SIDE PANEL EMERGENCY ESCAPE LIGHT ASSY DAMAGED. REPLACED 2E EMERGENCY LIGHT ASSY. OPS OK.
THE 12B LAPTOP POWER OUTLET SMOKED WHEN PLUGGED IN, PER F/A PASSENGER STOPPED USING IT. TESTED PLUG. NO SIGN OF BURNED PINS OR SMOKE DAMAGE. UNABLE TO DUPLICATE PROBLEM.
SILENT SURGES DETECTED IN NR 1 ENGINE. ENGINE REPLACED AT SFO DUE TO HEAVY HP COMPRESSOR BLADE DAMAGE FOUND BY BORESCOPE INSPECTION. ONE BLADE WAS FOUND BROKEN IN THE AIRFOIL. SUSPECT DAMAGE TO BE THE RESULT OF VSV INNER TRUNNION BUTTON LIBERATION. THIS IS A FIRST RUN HP COMPRESSOR. FINDINGS TO BE UPDATED FOLLOWING HP COMPRESSOR TEARDOWN. ESTIMATE 03/31/08.
FAINT SMELL OF HOT PLASTIC OR ELEC INSULATION NEAR DOOR 4R AT AFT CAPC. SUSPECT COFFEE WARMER HAD EXCESSIVE COFFEE RESIDUE. CLEANED WARMER. ALSO OPEN ACCESS PANELS IN AFT LAV AND GALLEY TO THE RESPECTIVE LIGHTS BALLAST AND INSPECTED FOR ANY DEFECTS, INSPECTED CSAP AT DOOR 4 LT ALL COMPONENTS SATISFACTORY. NO ABNORMAL SCENTS OR ODOR. AC OK FOR SERVICE
BATTERY CHARGER AND APU BATTERY MESSAGES DISPLACED ON STATUS PAGE. REPLACED BATTERY AND CHARGER PER MM24-31-05 & MM24-31-06. OP CHECKS READY FOR SERVICE.
LIGHTNING STRIKE DAMAGE ABOVE COCKPIT AT STA 219 LBL 9.5 AND STA 201 LBL 8. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.
STA 256 LBL 10 IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE BS 256 LBL 10. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.
STA 285.5 STR 2L IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE STA 285.5 STR 2L. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.
STA 360.0 STR 2L IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE STA 360 STR 2L. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.
UPPER FUSELAGE SKIN AT STA 247 STR 1L LBL 4 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: INSTALLED TRIPLER REPAIR.
FLIGHT ATTENDANTS REPORT DOOR 4 RIGHT IS FROZEN AND WILL NOT DISARM. DOOR 4R UNABLE TO DISARM. RAISED TEMP IN AC TO THAW DOOR ARMING CABLE. CYCLED DOOR AND ARM DISARM LEVER NUMEROUS TIMES. APPLIED ICE RELEASE TO DOOR AND GIRT BAR MECH. PROBLEM REPEATED IN DEN. REPLACED ARMING PUSH PULL CABLE. OP CHKS NORMAL.
DENT IS FOUND AT EXTERNAL FUSELAGE SKIN AT STA 677.5, BETWEEN STR 27L & 28L. ACCOMPLISHED HEFC INSPECTION IN DENTED AREA, INTERNAL AND EXTERNAL. NO CRACK IS FOUND. MEASURED DENT: 3.0" X 3.5", Y=.120". ACCOMPLISHED REPAIR PER EN777-53-0020-02 AND UA EVA-60625. REPLACE STR 27L TO 28L SHEAR TIE ANGLE. THE REPAIR IS A CATEGORY B REPAIR REQUIRES VISUAL REINSPECTION 094972 BEGINING AT 30000 CYCLE FROM CURRENT CYCLE COUNT. THE REPETITIVE INSPECTION WILL BE AT INTERVAL 0F 8000 CYCLE THEREAFTER. NOTIFIED SMAC-LINE MAINTENANCE TO REMOVE THE CF ITEM ONCE THE EC IS IMPL EMENTED. THE REPAIR IS FAA APPROVED.
RT ENGINE SEIZED AT 14000 FT. AMBER ALERT DECLARED. ENGINE REPLACED AT IAD. SHOP TEARDOWN FOUND ONE HPT STAGE-2 BLADE FAILED UNDER THE THE PLATFORM DUE TO STRESS CORROSION CRACKING. SIX (6) ADJACENT BLADES WERE FRACTURED, AS A RESULT, APPROXIMATELY 1/4" ABOVE THE PLATFORM, THEREBY CAUSING HEAVY VIBRATION. SEVENTEEN (17) OTHER STAGE-2 BLADES WERE SIMILARILY FRACTURED 1/4" ABOVE THE PLATFORM. ALL MAINLINE BEARINGS SUFFERED HEAVY RESULTANT DAMAGE, ANF THE N1 & N2 ROTORS WERE FROZEN.THIS WAS A FIRST RUN ENGINE.
EMERGENCY EEL LIGHT INOP AT SEAT 1E FWD. REPLACED LIGHT ASSY. OPS CHECK OK.
DENTS AT STA 1660 BETWEEN STR 43R & STR 44R AND BETWEEN STR 44R & STR 45R. BOTH DENTS ARE APPROX 7 INCHES IN DIAMETER, SMOOTH BUT WITH A .25 INCH DEPTH. FWD OF AFT PIT BELOW FLOOR LEVEL. DENT AT STA1660 BETWEEN STR 43R & STR 44R, DENT AT STA 1660 BETWEEN STR44R & STR45R. BOTH DENTS ARE APPROX. 7" IN DIAMETER, SMOOTH BUT WITH A .25" DEPTH. NO STRINGER DAMAGE DISCOVERED. BACO PROVIDED DETAILS OF REPAIR. CUT OUT BOTH DENTS. CUT DOUBLERS TO FINAL SIZE AND INSTALLED. CARGO LOADER DAMAGE.
ARMREST SIDE ONE EMERGENCY PATH MARKING LIGHT BROKEN AT SEAT 1E. REPLACED LAMP ASSY.
NR 1 ENGINE AFT SAILTAIL COMPT LWR BKHD FITTING FAIL CONDUCTIVE TEST. NR 1 ENGINE AFT SAILTAIL COMPT LWR BKHD FITTING FAILED CONDUCTIVE TEST BECAUSE OF HEAT DAMAGE. MAJOR REPAIR WAS ACCOMPLISHED PER EVA UA-EVA-50816B.
BROKEN PRV FOUND IN SLIDE WHEN OPENED FOR OVERHAUL. SLIDE WOULD NOT HOLD AIR PRESSURE. DAMAGED PRESSURE RELIEF VALVE WAS OBSERVED DURING SLIDE/RAFT COMPONENT SHOP MAINTENANCE. THE EXACT CAUSE OF THE DAMAGE TO THE PRESSURE RELIEF VALVE COULD NOT BE DETERMINED, BUT IT IS SPECULATED IT WAS DAMAGED DURING THE LAST PACKING PROCESS. PRESSURE RELIEF VALVE ASSEMBLY WAS REPLACED.
LT SIDE FUSELAGE DAMAGED. MAJOR REPAIR ACCOMPLISHED. DAMAGE TO FUSELAGE SKIN AND STRINGER AT APPROXIMATELY BS 645, STR 29L - 30L FOLLOWING CONTACT WITH AIRSTAIR CASE. MAJOR REPAIR ACCOMPLISHED ON EVA ORD-6140 -A- AND ORD-6142.
LT ENG FIRE LOOP AND LT ENG OVERHT DETECT EICAS MESSAGES. OIL QTY AND OIL PRESSURE DROPPED. ENGINE SHUTDOWN. EMERGENCY DECLARED. ENGINE REPLACED. FOUND ONE HPT STG-2 BLADE FAILED AT AIRFOIL MID-SPAN AS A RESULT OF INTERNAL SULFIDATION. ANOTHER BLADE FAILED NEAR THE AIRFOIL PLATFORM, AS A RESULT OF CONTACT WITH DEBRIS FROM 1ST BLADE. RESULTED IN VIBRATION. OVER TIME, CAUSED FAILURE OF THE FIRE/OVERHEAT LOOPS, & RESULTED IN CRACKING OF OIL PRESSURE LINE BETWEEN SERVO FUEL HEATER & AIR OIL HEAT EXCHANGER. CAUSE OF BLADE SULFIDATION CONTAMINATION OF COOLING PASSAGES WITH TURBO-TIP COATING. PWA HAS CHANGED COATING PROCESS TO PRECLUDE FUTURE CONTAMINATION.
WIRES DETACHED FROM EMERGENCY EVAC LIGHTS ON SEAT SHROUD. REPLACED AFT EMERGENCY LIGHT ASSY.
INTERMITTENT PROBLEM WITH LEFT ENGINE FIRE DETECTION SYSTEM. THE NR 1 ENGINE OVERHEAT MESSAGE WAS A FALSE INDICATION. BOTH OF THE NR 1 ENGINE FIRE LOOPS WERE INSPECTED AND OPS CK'D WITH NO DISCREPANCIES FOUND. DUE TO LEFT CARD FAULT INDICATION FROM CMC, THE NR 1 ENGINE FIRE DETECTION CARD WAS REPLACED.
EMERGENCY LIGHTS AT SEAT 3F (FLOOR PROX) ARE INOP. *S/D* EMERGENCY PROX LIGHTS AT SEAT 3F WERE INOP DUE TO CHAFED OR DAMAGED WIRES NEAR THE THE SEAT DISCONNECT ALONG THE WIRE RUN WHICH CONTAINS THE INVERTERS. INSTALLED TEMPORARY REPAIR BY SPLICING WIRE HARNESS. PERMANENT REPAIR IS SCHEDULED FOR THE NEXT MAINTENANCE OPPORTUNITY.
ACRID-ONLY SMOKE SMELL IN COCKPIT AND CABIN NO SMOKE VISIBLE. OUT OF FL204 IN DESCENT BETTER BY 104. *S/D* REPLACED NR 1 ENGINE. SHOP INVESTIGATION REVEALED NO VISIBLE OIL IN THE ENGINE GAS PATH OR PNEUMATIC DUCTS AND NO EXTERNAL OIL LEAKS. NO OIL IN FAN HUB OR SPINNER. VACUUM TEST OF NR 1, 1.5 & 2 BEARING COMPARTMENTS INDICATED LEAKAGE ONE PPH OVER LIMIT. DISASSEMBLY REVEALED LIGHT OIL COATING ON INNER WALL OF LPC DRUM. COMPONENT TEST OF NR 1.5 & 2 BEARING CARBON SEAL ASSEMBLY REVEALED HIGH AIR LEAKAGE AT THE 1.5 CARBON SEAL OF 7.3 CU. FT. / MINUTE (LIMIT = 3.0 CU FT / MIN). POSSIBLE CAUSE OF COCKPIT AND CABIN ODOR IS OIL LEAKAGE PAST THE NR 1.5 CARBON SEAL.
REPORT OF ODOR IN AREA OF DOOR 4 RIGHT. FOUND CACP (CABIN AREA CONTROL PANEL) AT DOOR 4 RIGHT BURNED OUT. PULLED CIRCUIT BREAKER TO REMOVE POWER SUPPLY TO PANEL. *S/D* INSTALLED NEW CACP SCREEN (P/N: 285W0012-3). NO EVIDENCE OF AIRCRAFT ELECTRICAL SYSTEM PROBLEMS. AIRCRAFT RETURNED TO SERVICE WITH NO FURTHER DIFFICULTIES.
CREW REPORTED AFTER TAKEOFF AIRFRAME VIBRATION OF UNDETERMINED ORIGIN. AIRCRAFT RETURNED TO LAX.
ABOUT 45 MIN AFTER DEPART (ORD-FRA) FLT CREW RECEIVED ADVISORY MSG, FUEL PUMP L FWD INDICATING LEFT FORWARD (BOOST) FUEL PUMP OUTPUT PRESSURE LOW. ETOPS RESTRICTIONS APPLIED PER MEL. *S/D* RELAY (L FWD FUEL BOOST PUMP SWITCH) IN P320 IS NOT IN THE COMMANDED POSITION. TRIED TO RESET BY ACCOMPLISHING FIM 28-22 TASK 826, NO HELP. MSG BECAME NOT ACTIVE BUT PUMP STILL INOPERATIVE. CHECKED PHYSICALLY AND PUMP NOT OPERATING. PERFORMED QUICK CHECK FOR ELECTRICAL POWER AT CONNECTOR AND FOUND AVAILABLE. REPLACED LEFT FORWARD BOOST PUMP (P/N: 568-1-29115-002) AND PERFORMED OPS CHECKS PER AMM 28-22-05.