N805DE

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
DELTA AIR LINES, INC. (DALA)Operatoron 1998-10-08Operator named in NTSB report

Accident & incident history

Incident · 1998-10-08 Operator named in NTSB report
Douglas MD-11 No injuries Part 121DELTA AIR LINES, INC.

Operated by DELTA AIRLINES, INC. (per NTSB report)

Source: NTSB case DCA99RA002

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

30 reports on file, 1995-08-25 – 2002-12-13.

FLT CONT AFFECTED · 2002-12-13 Matched by certificate designator
ATA 2740

Part: CONTROL VALVE — MALFUNCTIONED (PRIMARY TRIM) · airframe 48,540 hrs · 6,233 cycles

AT 5000 FT, FLAPS AT 15 AUTOPILOT NR 2 ENGAGED. RECEIVED STAB OUT OF TRIM AND STAB IN MOTION ALERTS. DISCONNECTED AUTOPILOT AND A/C PITCHED UP 20 DEGREES. MANUALLY TRIMED STAB OK. CHECKED ELEVATOR RIGGING PER MM CHECKS OK. CHECKED HI RATE STAB TRIM OPERATION, ALL OK. REPLACED PRIMARY TRIM CONTROL VALVE PER MM 27- 43-40-4, NO LEAKS NOTED. RAN FUNCTION TEST OF HORIZONTAL STAB TRIM RATE AND ADJUSTMENT AND TEST SYST CHECKS OK.

Source: SDR DLM11021435
WARNING INDICATION · 2002-11-05 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 48,102 hrs · 6,175 cycles

FOUND DURING EMERGENCY EQUIPMENT CHECK. L-3 EMERGENCY FLASHLIGHT PULLED AND STOWED 180 DEGREES OUT IN ITS CRADLE BATTERY DRAINED. REPLACED SAME.

Source: SDR DLM11021293
OTHER · 2002-08-06 Matched by certificate designator
ATA 7200

Part: ENGINE — MALFUNCTIONED (NR 2) · airframe 46,952 hrs · 5,977 cycles

LOUD NOISE AFTER T/O FROM AFT PORTION OF A/C POSSIBLE COMP STALL OR CARGO SHIFT NO IRREGULAR ENGINE PARAMETERS NOTICED. RETURNED TO BASE AFTER CONSULTING OCC DUMPED FUEL FROM 520-480 LANDING AT APPROX 474000 FLAPS 50. REPLACED NR 2 ENGINE PER TRANS 8T201AD ON R/C 1 THROUGH 33.

Source: SDR DLM11020924
FALSE WARNING · 2002-02-01 Matched by certificate designator
ATA 2612

Part: WARNING SYSTEM — FALSE INDICATION (COCKPIT) · airframe 44,799 hrs · 5,654 cycles

NUMBER 3 ENGINE (RIGHT) FIRE INDICATION. FOLLOWED PROCEDURE. BOTH BOTTLES FIRED WITH LIGHT REMAINING ON. DIVERT TO KBOS. EXTERNAL INSPECTION SHOWED NO EVIDENCE OF FIRE ON THE GROUND, INSPECTED ENG AND NO EVIDENCE OF FIRE. HARD FAULT NUMBER 3 ENG FIRE DETECTOR T/S PER FIM FAULTED FDCU INTERNAL FAULT AND LOOP A FAULT. INSPECTED ALL LOOPS AND HARNESSES NTF RESISTANCE FROM FDCU OKAY, OHMED AT ALL LOOPS RESISTANCE WITHIN LIMITS. REPLACED FDCU OPS NORM, RTS GOOD VERIFIED IN NR 2 SPOT ITEM FOLLOWED REINSTALLED ORIG, ALL NOW TEST NORM.

Source: SDR DLM11020125
Earlier reports · 1995–2001 · 26 reports

2001

OTHER · 2001-09-04 Matched by certificate designator
ATA 3520

Part: GENERATOR — ACTIVATED (CABIN) · airframe 43,313 hrs · 5,458 cycles

OXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEATS 48JH. REPLACED SAME.

Source: SDR DLM11011485
OTHER · 2001-09-04 Matched by certificate designator
ATA 3520

Part: GENERATOR — ACTIVATED (CABIN) · airframe 43,313 hrs · 5,458 cycles

OXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEAT 11 G. REPLACED SAME.

Source: SDR DLM11011483
OTHER · 2001-09-04 Matched by certificate designator
ATA 3520

Part: GENERATOR — ACTIVATED (CABIN) · airframe 43,313 hrs · 5,458 cycles

OXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEAT 11 C. REPLACED SAME.

Source: SDR DLM11011482
OTHER · 2001-09-04 Matched by certificate designator
ATA 3520

Part: GENERATOR — ACTIVATED (CABIN) · airframe 43,313 hrs · 5,458 cycles

OXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEATS 55AB. REPLACED SAME.

Source: SDR DLM11011484
FLUID LOSS; WARNING INDICATION · 2001-05-19 Matched by certificate designator
ATA 2913

Part: PUMP — FAILED (NR 3 ENGINE) · airframe 42,059 hrs · 5,301 cycles

NR 3 HYDRAULIC, RIGHT EDP FAILED FOR TEMP. REPLACED BOTH NR 3 HYDRAULIC PUMPS. REPLACED SYSTEM FILTERS. SERVICED, BLED AND LEAK CHECKED SYSTEM.

Source: SDR DLM11010802
OVER TEMP · 2001-02-23 Matched by certificate designator
ATA 7261

Part: ENGINE — OVERSERVICED (NR 2 ENGINE) · airframe 40,940 hrs · 5,163 cycles

THE NUMBER TWO ENGINE WAS RUNNING AT 149 DEG CELSIUS TO 152 DEG CELSIUS IN CRUISE. THIS WAS APPROX 40 DEG CELSIUS ABOVE NR 1 AND NR 3. THE FLIGHT (79) DIVERTED TO PDX. FOUND ENGINE OIL OVERSERVICED. REMOVED OIL TO PROPER LEVEL.

Source: SDR DLM11010326
INADEQUATE Q C · 2001-02-21 Matched by certificate designator
ATA 5210

Part: HANDLE — MISLOCATED (L-1 DOOR) · airframe 40,904 hrs · 5,159 cycles

L1 DOOR OPEN HANDLE FOUND TO HAVE INSUFFICIENT CLEARANCE TO CREW REST MODULE. MODIFIED MODULE PER ERA 388450/14.

Source: SDR DLM11010305

2000

SMOKE/FUMES/ODORS/SPARKS · 2000-08-15 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 38,242 hrs · 4,884 cycles

BRIEF ELEC SMELL IN COCKPIT ONLY, DID NOT REOCCUR. CHECKED WIRING BEHIND CIRCUIT BREAKER PANELS, RAN AC PACKS AND NO DISCREPANCIES NOTED.

Source: SDR DLM11001572
OTHER · 2000-06-29 Matched by certificate designator
ATA 3160

Part: DISPLAY — FAILED (COCKPIT) · airframe 37,539 hrs · 4,803 cycles

F/O FMS MCDU FAILED POM PROC NO HELP. DIVERTED TO PDX - REPLACED F/O MCDU.

Source: SDR DLM11001233
PARTIAL RPM/PWR LOSS · 2000-03-20 Matched by certificate designator
ATA 7320

Part: FMC — MALFUNCTIONED (NR 1 ENGINE) · airframe 36,137 hrs · 4,662 cycles

NR 1 ENG INDICATIONS FLUCTUATING AT CRUISE FL350. FUEL FLOW N1, N2 EPR ALL FLUCUATING SLIGHTLY BUT NOTICABLE. REPLACED NR 1 FMU PER M/M. LEAKED CHECKED SATISFACTORY, RAN ENGINE PER PFHB, ENGINE TEST NUMBER 3 ALL CHECKS SATISFACTORY.

Source: SDR DLM11000558

1999

OTHER · 1999-12-10 Matched by certificate designator
ATA 5753

Part: SKIN — DAMAGED (TE FLAP)

RIGHT I/B FLAP VANE LOWER SKIN, TIRE DAMAGE 24 X 22 DAMAGE TO LOWER SKIN AND CORE OF FLAP VANE. AUTHORIZED PREPREG CARBON FIBER COMPOSITE REPAIR.

Source: SDR DLM11992742
SMOKE/FUMES/ODORS/SPARKS · 1999-06-28 Matched by certificate designator
ATA 2530

Part: OVEN — FAILED (G-7 GALLEY)

IN CRUISE, THE NR 327 G-7 GALLEY OVEN HAD AN ELECTRICAL ODOR. CREW HAD TO PULL THE C/B DUE TO IT NOT POPPING. STRONG SMELL AND SMOKE IN AFT AREA. REPLACED OVEN.

Source: SDR DLM11991451
SMOKE/FUMES/ODORS/SPARKS · 1999-06-28 Matched by certificate designator
ATA 2530

Part: OVEN — FAILED (GALLEY)

SMOKE NOTICED COMING FROM G-8 GALLEY OVEN DURING FLIGHT. OVEN SHUT OFF. FOUND OVEN 327 FAN NOT RUNNING, CAUSING THE MOTOR TO OVERHEAT. REPLACED OVEN.

Source: SDR DLM11991458
VIBRATION/BUFFET · 1999-06-18 Matched by certificate designator
ATA 7200

Part: ENGINE — MALFUNCTIONED (NR 2)

LOUD NOISE REPORTED BY FLT ATTENDANTS AND TOWER, SLIGHT VIBRATION NOTED AT ROTATION RWY 9L IN ATL. SUSPECTED COMPRESSOR STALL. ENGINE INDICATIONS NORMAL. REPLACED NR 2 ENGINE.

Source: SDR DLM11991394

1998

SMOKE/FUMES/ODORS/SPARKS · 1998-10-08 Matched by certificate designator
ATA 3840

Part: COMPRESSOR — SEIZED (NR 1 WATER SYST)

AIRCRAFT DIVERTED INTO SNN WITH SMELL OF BURNING IN CABIN. IRISH AUTHORITIES REMOVED FDR AND CVR FOR ELAVUATION. AIRCRAF STILL IN SNN 100998 UNDER INVESTIGATION. NR 1 WATER SYS AIR COMP FAILED, BURNED WIRING TO COMPRESSOR.

Source: SDR DLM11982096
NO TEST · 1998-08-28 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

NR 3 EMERGENCY BATTERY PACK TESTED LOW DURING SYSTEM MAINT TEST. REPLACED POWER SUPPLY.

Source: SDR DLM11981786
NO TEST · 1998-01-23 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

L2 EMER EXIT BATTERY PACK FAILS TEST, READS LOW. REPLACED L-2 BATTERY PACK, CKS GOOD.

Source: SDR DLM11980210

1997

NO TEST · 1997-07-07 Matched by certificate designator
ATA 2560

Part: SWITCH — SHORTED (R4 DOOR SLIDE)

ON L/O CHECK, FOUND PUSH TO TEST INOP FOR R-4 DOOR SLIDE LOW PRESS WARNING. REPLACED LIGHT SWITCH ASSY DUE PTT FUNCTION SHORTED, LIGHT OPS NORMAL.

Source: SDR DLM11971307
SMOKE/FUMES/ODORS/SPARKS · 1997-05-23 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — ACTIVATED (NR 3 RT LAV)

F/A REPORTED, PASSENGER CAUGHT SMOKING IN 3R LAV. PAX DROPPED CIGARETTE IN LAV TRASH BIN WHICH CAUSED A SMOLDERING FIRE. EXTINGUISHED BY COFFEE AND WATER. INSPECTED TRASH BIN THERMAL SENSOR, NO HEAT DETECTED. INSPECTED TRASH BIN FIRE EXTINGUISHER, NOT DISCHARGED. PERFORMED SATISFACTORY TEST OF LAV SMOKE DETECTOR AND INSPECTED CHUTE DOOR CONDITION. CONTENTS OF CONTAINER REVEALED CIGARETTE. HOWEVER, NO EVIDENCE OF FIRE.

Source: SDR DLM11970993
OTHER · 1997-05-06 Matched by certificate designator
ATA 3510

Part: OXYGEN GENERATOR — EXPELLED (CABIN)

FOUND ON L/O, 4R F/A EMERGENCY O2 EXPELLED. REMOVED AND REPLACED SAME, OK FOR SERVICE.

Source: SDR DLM11970868
NO TEST · 1997-04-11 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

EMERGENCY TRACK LIGHTS AT 11G INOP AND AT 14G 3E F/C GALLEY FWD RED LIGHT INOP.

Source: SDR DLM11970650

1996

WARNING INDICATION · 1996-01-01 Matched by certificate designator
ATA 2420

Part: WIRE — DAMAGED (NR 1 ENGINE)

GENERATOR FEEDER CABLES DAMAGED, DUE TO SHORTING IN PYLON.

Source: SDR DLM11960006

1995

NO TEST · 1995-11-01 Matched by certificate designator
ATA 3350

Part: EEL MODULE — INOP (1L CABIN DOOR)

2R DOOR SLIDE LIGHT INOP. REPLACED LIGHT MODULE, OPERATION NORMAL.

Source: SDR DLM11954170
NO TEST · 1995-11-01 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (2R CABIN DOOR)

2R DOOR SLIDE LIGHT INOP. INSTALLED BATTERIES IN CORRECT POSITION, OPERATION NORMAL.

Source: SDR DLM11954175
NO TEST · 1995-09-05 Matched by certificate designator
ATA 3350

Part: EEL BULB — FAILED (CABIN)

DURING LAYOVER, EMERGENCY FLOOR TRACK LIGTHS AT 40AB TO 47AB OUT. RETERMINATED BROKEN WIRE, RELAMPED AND OPERATION NOW NORMAL.

Source: SDR DLM11953608
NO TEST · 1995-08-25 Matched by certificate designator
ATA 3350

Part: EEL BULB — FAILED (CABIN)

FLOOR TRACK LIGHTS INOP AT SEAT 1E AND FWD LEFT GALLEY. RELAMPED.

Source: SDR DLM11953505