N807MM

CANADAIR LTD CL-600-2A12 · 1983 · Fixed-wing multi-engine · 2 engines · 22 seats · Valid Registration

Registered owner: POLLARD SPARES LLC, TX (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
PREMIER AIR CHARTER LLC (QJOA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2014-04-22 – 2015-06-13.

WARNING INDICATION · 2015-06-13 Matched by certificate designator
ATA 3600

Part: WARNING LIGHT — ILLUMINATED (BLEED SYS) · airframe 9,753 hrs · 5,760 cycles

RIGHT FUSELAGE BLEED WARNING CAME ON.

Source: SDR LOMA2015FA0000280
FALSE WARNING · 2014-12-04 Matched by certificate designator
ATA 2600

Part: LOOP — DEFECTIVE (10TH STAGE) · airframe 9,620 hrs

RIGHT 10TH STAGE BLEED WARNING LIGHT CAME ON DURING DECENT. LANDED FOR REPAIR. REPLACED RT 10TH STAGE BLEED AIR WARNING LOOP A ELEMENT.

Source: SDR LOMA2014FA0000687
WARNING INDICATION · 2014-11-25 Matched by certificate designator
ATA 3610

Part: VALVE — LEAKING (E/E BAY) · airframe 9,621 hrs

RIGHT 10TH STAGE WARNING LIGHT CAM ON DURING DECENT.

Source: SDR LOMA2014FA0000688
OVER TEMP · 2014-11-18 Matched by certificate designator
ATA 7532

Part: SHUTOFF VALVE — LEAKING (BLEED AIR) · airframe 9,613 hrs

RIGHT 10TH STAGE BLEED AIR WARNING ILLUMINATED. DIVERTED FOR REPAIR. REPLACED 10TH AND 14TH STAGE BLEED AIR SHUTOFF VALVES.

Source: SDR LOMA2015F00009
FALSE WARNING · 2014-04-22 Matched by certificate designator
ATA 2613

Part: DETECTION SYS — FALSE ACTIVATION (OVERHEAT) · airframe 9,375 hrs · 5,565 cycles

RIGHT 10TH STAGE DUCT FAIL LIGHT ILLUMINATED DURING FLIGHT. TROUBLESHOT AND FOUND NO BLEED AIR LEAKS FROM RT 10TH STAGE MANIFOLD. FALSE INDICATION. REPLACED ALL OVERHEAT DETECTOR LOOPS FOR RT 10TH STAGE BLEED AIR LEAK DETECTION SYSTEM.

Source: SDR LOMA2014042500279