N89313
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| UNITED AIRLINES INC | Operator | 2018-04-11 – 2018-04-11 | Operator named in NTSB report |
| UNITED AIRLINES, INC. (CALA) | Operator | 2018-04-11 – 2018-04-11 | Operator named in NTSB report |
Accident & incident history
Maintenance disclosures
RIGHT SLAT NR 2 PICCOLO TUBE IS GOUGED IN OTBD WELD. REPAIRED PER ETD.
FWD E&E BAY DOOR OPEING RH FRAME IS CHAFED JUST AFT OF FWD TRACK. REPAIR
CABIN FLOOR SEAT TRACK AT FR25 - FR26 LH TRACK HAS TWO GOUGES. REPLACED
SEAT TRACK BEAM LBL11 IS CORRODED AT FR19. REPLACED PER SRM.
LAV WASTE DOOR CUTOUT INTERNAL DOUBLER FWD I/B SIDE CORRODED. REPAIRED
PANEL 195ML HAS EVIDENCE OF CORROSION AROUND SCREW HOLES. REPAIRED PER ETD.
PYLON PANEL 429ML HAS MULTIPLE CHAFED AREAS ON BACK SIDE. REPAIRED PER ETD.
PYLON PANEL 419NR HAS MULTIPLE CHAFED AREAS ON BACK SIDE. REPAIRED PER ETD.
PYLON PANEL 419ML HAS MULTIPLE CHAFED AREAS ON BACK SIDE. REPAIRED PER ETD.
SEAT TRACK BEAM RBL11 IS CORRODED BETWEEN FR14-FR18 IN MULTIPLE PLACES. REPLACED PER SRM.
MID AVIONICS BAY PLUG DOOR PANEL 147AL HAS MULTIPLE SCRATCHES AROUND ENTIRITY OF DOOR ON FRAME. REPAIRED PER ETD.
PYLON PANEL 429NR HAS MULTIPLE CHAFED AREAS ON BACK SIDE. REPAIRED PER ETD.
LH OVER PYLON WING LE EDGE PANEL CHAFED. REPAIRED
LH OVER PYLON WING LE EDGE PANEL CHAFED. REPAIRED
FR14 CROSSBEAM BETWEEN RBL11-RBL24 IS CORRODED. REPAIRED PER SRM.
L/H FLOOR SILL AT FR16 LBL40 IS CORRODED. REPLACED PER SRM.
FWD WET AREA FLOOR SUPPORT AT FR14 RBL14 IS CORRODED. REPLACED PER SRM.
AFT WET AREA FLOOR SUPPORT AT FR87 RBL24 IS CORRODED. REPLACED PER SRM.
AFT WET AREA GUSSET AT FR90 BL0 IS CORRODED. REPLACED PER SRM.
FUSELAGE SKIN AT SPLICE JOINT BETWEEN FR90-FR91 AND STR26R-STR28R IS CORRODED. REPAIRED PER ETD.
FR17 CROSSBEAM AT RBL24 CORRODED. REPAIRED
RH FLOOR DOUBLER AT FR14 RBL36 CORRODED. REPLACED
AFT WET AREA TEXAS GUSSET AT FR90 RBL24 CORRODED. REPLACED
AFT WET AREA GUSSET AT FR90 LBL10 CORRODED. REPLACED
AFT WET AREA FLOOR SUPPORT AT FR86 RBL24 CORRODED. REPLACED
AFT WET AREA FLOOR SUPPORT AT FR85 RBL24 CORRODED. REPLACED
FWD COAT CLOSET PHOTOILLUMINASENT INOPERATIVE. R & R FWD PHOTLUMINESCENT STRIP.
EMER PATH LIGHTING 1ST CLASS INOP - PLACED ON MEL
EMER LIGHT BATT FAULT /PREFORMED GENERIC IO MODULE 2A RESET TEST, FAULT CLEARED, OPS CHECK GOOD, NO DEFECTS
CAPTAIN SIDE WINDSHIELD FRAME DAMAGED FURING NUTPLATE REPAIR. LH COCKPIT WINDSHIELD FRAME 3 MISDRILLED RIVET HOLES AND SCRATCHED. REPAIRED PER RO# E175-53-4577.
RH FWD SEAT TRACK CORRODED BETWEEN FR14 AND FR17
LH WHEEL WELL FR52 STUB ANGLE HAS 2 EACH CRACKS
RIGHT FLOOR SUPPORT CORRODED AT FRAME 84 RBL40
FLOORBEAM CORRODED AT FRAME 14, RBL 24.
RH FWD FLOOR DOUBLER AT FR14 RBL36 CORRODED
FLOOR GUSSET CORRODED AT FR89 AND RBL9
FWD LH SKIN HAS BIRD STRIKE JUST AFT OF THE RADOME
RT MOP SILL CORRODED AT FR 88. REMOVED AND REPLACED MOP SILL.
GUSSET AT FR 90 AND RBL 9 CORRODED. REMOVED AND REPLACE GUSSET.
RIGHT HAND SHEAR PLATE AT FR 87 CORRODED. REMOVED AND REPLACED SHEAR PLATE.
ANGLE BRACKET ON THE AFT SIDE OF FLOOR BEAM 17 AT RBL 28 CORRODED. REMOVED AND REPLACED BRACKET.
FLOOR PLATE IS CORRODED ON TOP OF FLOOR BEAM FR 12 TO FR 14 RBL 36 TO RBL 48. REMOVED AND REPLACED FLOOR PLATE.
GUSSET AT RBL 9 AND FR 89 CORRODED. REMOVED AND REPLACED GUSSET.
GUSSET AT FR 89 AND RBL 27 CORRODED. REMOVED AND REPLACED GUSSET.
FLOOR BEAM RBL 10 CAP AND SEAT TRACK HAS NUMEROUS CORROSION SPOTS ON THE TOP AND BOTTOM SIDES BETWEEEN FLOOR BEAMS 12 THRU 21. REMOVED AND REPLACED SEAT TRACK FLOOR BEAM.
FLOOR BEAM LBL 10 CAP CORRODED TOP SIDE JUST AFT OF FLOOR BEAM 17. REPAIRED FLOOR BEAM.
GUSSET AT FR 89 AND LBL 9 CORRODED. REMOVED AND REPLACED GUSSET.
INTERCOSTAL AT FR 88 LBL 9 CORRODED. REMOVED AND REPLACED INTERCOSTAL.
FWD FA FLASHLIGHT INOP-NOT BLINKING. PLACED ON MEL.
AFT FA FLASHLIGHT INOP-REPLACED BATTERY
CA FLASHLIGHT RED INDICATOR INOP. REPLACED BATTERY
AFT FA FLASHLIGHT INOP. PLACED ON MEL.
AFT FA FLASHLIGHT INOP. PLACED ON MEL.
AFT FA FLASHLIGHT IND INOP. REPLACED BATTERY.
FWD FA FLASHLIGHT INOPERATIVE.
FLOOR SUPPORT SPLICE HAS CORROSION, FS 24458.0, FRAME 89, RBL 304.8, WATER LINE 490. REMOVED AND REPLACED SUPPORT SPLICE IAW EMB 175 SRM 51-43-03.
FLOORBEAM CORRODED AT FS 24098 - 24868, RBL 876.3-1028.7, WATER LINE 490. REMOVED AND REPLACED IAW SRM 51-42-01.
GUSSET CORRODED AT BS 24868 RBL 584.2 WATERLINE 490. REMOVED AND REPLACED GUSSET IAW ERJ175 SRM 51-42-02.
FWD FA FLASHLIGHT INOP. PLACED ON MEL.
PHOTO LUM FLOOR STRIP IN FRONT OF COAT CLOSET INOP. PLACED ON MEL.
CAPTAIN`S FLASHLIGHT NOT CHARGED. REPLACED FLASHLIGHT BATTERIES.
CAPTS FLASHLIGHT INOPERATIVE.
FWD SECTION EMERGENCY LIGHT STRIP INOPERATIVE.
F/O'S FLASHLIGHT INOPERATIVE.
CAPTAIN`S FLASHLIGHT INOPERATIVE.
AFT GALLEY FLASHLIGHT INOPERATIVE. REPLACED BATTERY.