N909BP
Registered owner: GSH TRAVEL LLC, OK (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| Protocom Aviation, LLC (4PMA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
3 reports on file, 2021-12-13 – 2026-08-02.
Part: COVER — SEPARATED (RIGHT ENGINE) · airframe 2,174 hrs · 1,589 cycles
HONDAJET N909BP, 42000099, TAXIED OUT ON SUNDAY, AUGUST 2, AND THE LINE SERVICE PERSONNEL FOUND A 7" X 2" CURVED STAINLESS-STEEL PLATE/PIECE WITH P/N - 4JQT4-13121-Q0A-0100 LAYING ON THE GROUND WHERE THE AIRCRAFT HAD PARKED. A SECUITY VIDEO SHOWED AN OBJECT BEING EJECTED FROM THE EXHAUST PATH OF THE RIGHT ENGINE. HONDAJET TECH SUPPORT CONFIRMED THAT THIS WAS ONE OF THE "GG CASE BOLT COVERS", ONE OF 6 TOTAL PER ENGINE. HONDAJET TECH SUPPORT FURTHER STATED THAT THESE COVERS HAD BEEN FOUND MISSING AND/OR BROKEN IN SEVEREAL ENGINES THAT HAD BEEN REMOVED FOR OTHER MAINTENANCE (POSSIBLY LOSING THEIR COVERS IN FLIGHT), AND ONLY ONE OTHER COVER HAD BEEN FOUND FROM AN OPERATIONAL AIRCRAFT. A BORSCOPE INSPECTION OF BOTH ENGINES ON 42000099 WAS ACCOMPLISHED, VERIFYING THAT ONE COMPLETE COVER WAS MISSING FROM THE RIGHT ENGINE AND THAT ABOUT 25% OF A COVER WAS MISSING FROM THE LEFT ENGINE. HONDAJET AND GE HONDA AERO ENGINES ISSUED A LETTER FOR CONTINUED OPERATION.
Part: BRAKE — FAILED (ZONE 700) · airframe 1,249 hrs · 848 cycles
RH BRAKE LOCKED UP ON LANDING
Part: COMPENSATOR — FAILED (ZONE 700) · airframe 570 hrs
NORMAL BRAKE FAIL CAS MESSAGE ILLUMINATED