N969MA
Registered owner: VENABLE GROUP LLC, MS (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| Air MD L.L.C. (YEWA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
3 reports on file, 2015-07-17 – 2024-07-25.
Part: SPACER — OUT OF LIMITS · airframe 15,675 hrs · 13,410 cycles
THROTTLE LINKAGE SPACER OUT OF POSITION CAUSED THE PROPELLER TO TRY TO GO INTO BETO RANGE EARLY DURING FINAL APPROACH TO RWY 18R AT KLRD. SPACER WAS LATER ADJUSTED PROPERLY, GROUND ENGINE RUN WAS NORMAL. ACFT RETURNED TO SERVICE 26 JULY 24.
Part: LIMIT SWITCH — MALFUNCTIONED (MLG) · airframe 15,089 hrs · 12,635 cycles
LANDING GEAR FAILED TO EXTEND NORMALLY. WAS ABLE TO EXTEND THE GEAR USING ABNORMAL PROCEDURE. LANDED WITHOUT EVENT. SUSPECT DOWN LIMIT SWITCH. SUPPLEMENTAL INFORMATION
Part: BLOWER — BURNED OUT (ZONE 100) · airframe 12,546 hrs · 10,137 cycles
AFTER TAKE OFF, PASSING THROUGH 16,000 FEET, OBSERVED AND SMELLED SMOKE IN THE AIRCRAFT. IT APPEARED TO ME TO BE VERY LIGHT GREY SMOKE, AND HAD AN ACRID SMELL AND WAS SLIGHTLY IRRITATING TO THE EYES AND THROAT. THE MED CREW IN THE REAR SAID THEY COULD ALSO SEE AND SMELL THE SMOKE. WE IMMEDIATELY REQUESTED AND RECEIVED CLEARANCE TO RETURN TO THE DEPARTURE AIRPORT AND LANDED PROMPTLY AND SAFELY WITHOUT ANY INCIDENT. NO EMERGENCY SERVICES WERE REQUIRED NOR REQUESTED. ON THE GROUND A LOCAL MECHANIC WAS LOCATED. WORKED WITH LIFETEAM MAINTENANCE, PERFORMED GROUND OPERATION CHECKS AND COULD NOT DUPLICATE. DID LOCAL AREA TEST FLIGHT. COULD NOT DUPLICATE. AIRCRAFT WAS TAKEN TO NEWTON FOR RE-INSPECTION. LIFETEAM FOUND THE FWD VENT BLOWER HAD FAILED. BLOWER HAS BEEN REPLACED AND AIRCRAFT RETURNED TO SERVICE. NO RECORD OF INSTALLATION WAS FOUND. COULD HAVE BEEN INSTALLED BY THE FACTORY.