ADDISON JET MANAGEMENT INC

Part 135 operator · designator I5JA

Data confidence: All records on this page are linked by a shared certificate number or aircraft registration (N-number).

Also recorded as: ADDISON JET MANAGEMENT INC, TRINITY PRIVATE JET CHARTER

Accident & enforcement record

Events that happened, regardless of the operator's own reporting. Each links to its public source.

NTSB accidents & incidents

No NTSB accidents or incidents linked to this operator.

FAA enforcement actions

FAA enforcement records haven't been loaded into GroundCheck yet, so none can be shown — a gap in our data, not evidence of a clean enforcement history.

Maintenance disclosure history

Service Difficulty Reports are self-reported maintenance findings. The NUMBER of reports is not a measure of reliability — diligent operators file more, not fewer. These are shown for transparency, not as a negative signal.

8 reports on file.

B · 2013-08-22 Matched by certificate designator
N325JF · ATA 2120

30 MINUTES BEFORE LANDING, DETECTED AN ELECTRICAL BURNING ODOR THROUGHT ENTIRE CABIN. TURNED OFF PC POWER SYS IMMEDIATELY AND ODOR SLOWLY WENT AWAY. F/A COULD NOT PINPOINT WHERE THE ODOR WAS COMING FROM. AFTER TURNING PC POWER OFF, GEN 1, 3, 2, AND 4 LOADS WERE 65, 75, 95, AND 90 RESPECTIVELY. ACFT LANDED SAFETLY. MX PERFORMED TROUBLESHOOTING IAW FIM 21-20-00-810-801-A, BLOCK 1-6, 8-10, NO FAULTS FOUND. MX PERFORMED OPS TEST OF PASSENGER PC POWER STATIC INVERTER COOLING FAN IAW AMM 24-20-03-700-802-A. OPS CHECKED GOOD, NO DEFECTS NOTED. COULD NOT DUPLICATE.

Source: SDR 7GMB2013082300001 · FAA SDRS
K J · 2013-06-20 Matched by certificate designator
N325JF · ATA 2910

ON DESCENT AT 14,000FT, HYD 2 QTY LOW MESSAGE APPEARED, THEN FOLLOWED SHORTLY BY ENG 2 HYD PUMP FAIL MESSAGE. THE CREW DIVERTED DUE TO RUNWAY REQUIREMENT AND LANDED SAFELY. DURING VISUAL INSPECTION, PN 145-31063-409 HOSE FROM NR 2 ENGINE DRIVEN HYDRAULIC PUMP WAS FOUND TO BE WORN THROUGH DUE TO CHAFING. REPLACED THE HOSE WITH INTERCHANGEABLE, PN A9140-409. OPS CHECK AND LEAK CHECK GOOD.

Source: SDR 7GMB0201306244991 · FAA SDRS
O · 2013-06-15 Matched by certificate designator
N325JF · ATA 3020

NR 1 ENGINE ANTI-ICE PRESSURE TRANSDUCER TUBE FOUND BROKEN AT TRANSDUCER AND ENGINE AIR INTAKE ANTI-ICE DUCT. R & R WITH NEW. OPS CHECKED GOOD.

Source: SDR 7GMB2013006186181 · FAA SDRS
B · 2012-11-06 Matched by certificate designator
N325JF · ATA 2424

GEN 3 OFF BUS ON TAXI IN AFTER SHUTDOWN OF NR 2 ENGINE. SMELL OF SMOKE IN THE COCKPIT. PERFORMED FIM 21-20-00-810-801-A FOR SMELL OF SMOKE IN THE CABIN COCKPIT. NO ABNORMAL SMELL NOTED AT THIS TIME. AC RELEASED IAW MEL 24-31-01-2 CTRL # 768504B09. PLACARDS INSTALLED CW SP 24-31-01-2. PULLED C/B'S D8 & D9.

Source: SDR I06B2012114991 · FAA SDRS
L · 2012-09-26 Matched by certificate designator
N325JF · ATA 3397

2ND EMERGENCY FLOOR PROXIMITY STRIP LIGHT INOP, CONNECTOR WIRES BROKEN AT BASE. REMOVED DEFECTIVE UNIT AND INSTALLED SERVICEABLE (NEW) 2ND EMERGENCY FLOOR POXIMITY STRIP LIGHT IAW EMB135 AMM TASK 33-50-12-000/400-801-A. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED.

Source: SDR I06B201209274991 · FAA SDRS
L · 2012-09-26 Matched by certificate designator
N325JF · ATA 3397

3RD EMERGENCY FLOOR PROXIMITY STRIP LIGHT INOP, CONNECTOR WIRES BROKEN AT BASE. REMOVED DEFECTIVE UNIT AND INSTALLED SERVICEABLE (NEW) 3RD EMERGENCY FLOOR PROXIMITY STRIP LIGHT IAW EMB135 AMM TASK 33-50-12-000/400-801-A. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED.

Source: SDR I06B201209274992 · FAA SDRS
J · 2012-06-27 Matched by certificate designator
N325JF · ATA 7310

ON TAKEOFF ROLL "E1 FUEL IMPENDING BYPASS" MESSAGE WAS DISPLAYED ON EICAS. THE CREW ABORTED THE TAKEOFF AND RETURNED TO THE GATE. MAINTENANCE PERFORMED THE PROCEDURES PER THE EMB135 AMM AND REPLACED THE FILTER ELEMENT. NO VISUAL CONTAMINATION WAS FOUND IN THE FILTER ELEMENT.

Source: SDR I06B201206274672 · FAA SDRS
J · 2010-01-18 Matched by certificate designator
N325JF · ATA 7200

AFTER TAKEOFF AT APPROX 400 FT, PILOTS RECEIVED "LAV SMOKE" EICAS INDICATION. DECLARED EMERGENCY & RETURNED FOR LANDING AT DEPARTURE. ACFT GROUNDED UNTIL MX DETERMINES ROOT CAUSE. F/A INVESTIGATED ACFT LAV - OBSERVING NO FUMES OR SMOKE. ONCE ON THE GROUND FIRE DEPARTMENT COMPLETED EXTERNAL INSPECTION " NO INDICATION OF SMOKE OR FUMES". AFTER ALL PASSENGERS DEPLANED, FIRE DEPARTMENT BOARD TO INVESTIGATE LAV "NO INDICATION OF SMOKE OR FUMES". ACFT WAS TAKEN OUT OF SERVICE FOR MX EVALUATION. RESIDUAL ENG CLEANER IN BLEED AIR SYS & ASSOCIATED COMPONENTS. MX CONDUCTED ENG CORE WASHES DURING WEEKEND.

Source: SDR I06B2010 01 18 JF · FAA SDRS

Linked aircraft

N-numberMake / modelYearStatusLink basis
N202JPCESSNA 6501994Valid RegistrationMatched by certificate designator
N267CHMatched by certificate designator
N325JFCESSNA 6501990Valid RegistrationMatched by certificate designator
N820FJMatched by certificate designator
N87CEMatched by certificate designator
N886DLMatched by certificate designator
N888WYHAWKER BEECHCRAFT CORP HAWKER 850XP2008Valid RegistrationMatched by certificate designator
N955TXCESSNA 5252000Valid RegistrationMatched by certificate designator
N989STRAYTHEON AIRCRAFT COMPANY HAWKER 800XP2000Valid RegistrationMatched by certificate designator